Thermostats

Eurolamp Analog Room Thermostat Code: 147-44001

The Eurolamp 147-44001 analog room thermostat regulates the temperature within a range of 0 to 40 °C. It is wall-mounted, mains-powered and features a switch, with NO and NC contacts.

  • Type: Analog
  • ...

The Eurolamp 147-44001 analog room thermostat regulates the temperature within a range of 0 to 40 °C. It is wall-mounted, mains-powered and features a switch, with NO and NC contacts.

  • Type: Analog
  • Installation: Wall-mounted
  • Programming: Non-programmable
  • Power supply: Mains
  • Supply voltage: 220–250 V
  • Operating frequency: 50/60 Hz
  • Rated power: 2 kW
  • Current: 4...
See full description See full description
12 78 €
Delivery by Thu, 12 Nov
14,00 €   shipping cost
Sent from Greece
From Electronix 3.6 (59)
Greece
1 piece
See Central Heating on the page of Electronix

Learn more about invoicing

Description

Description

The Eurolamp 147-44001 analog room thermostat regulates the temperature within a range of 0 to 40 °C. It is wall-mounted, mains-powered and features a switch, with NO and NC contacts.

  • Type: Analog
  • Installation: Wall-mounted
  • Programming: Non-programmable
  • Power supply: Mains
  • Supply voltage: 220–250 V
  • Operating frequency: 50/60 Hz
  • Rated power: 2 kW
  • Current: 4 A
  • Temperature range: 0–40 °C
  • Temperature increment: 2.5 °C
  • Thermostat contacts: NO and NC
  • Connection: Terminal block
  • Switch: Yes
  • Colour: White
  • Material: UL 94 V-0 flame-retardant
  • Ingress protection rating: IP20
  • Operating temperature: −10 to 50 °C
  • Width: 7.5 cm
  • Height: 7.5 cm
  • Depth: 3 cm

Manufacturer

See full description

Specifications

Specifications

Product Number
147-44001

Dimensions

Type
Analog
Placement
Wall-mounted
Power Source
Electric Power
Width
7.5 cm
Height
7.5 cm
Length
3 cm

Features & Functions

Touch Screen
No
Smart
No
Cooling-Heating
No
Temperature Range
0 - 40 °C
Programming
Non-Programmable
Temperature Gradation
2.5 °C

Wireless Attributes

Wi-Fi
No
Bluetooth
No
ZigBee
No
Z-Wave
No
RF
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Reviews (5)

Reviews

  1. 1
  2. 4 stars
    0
  3. 1
  4. 2 stars
    0
  5. 3
Review this product

What do users say? AI-generated summary

The overall picture is negative: although one user says it works normally, reviewers repeatedly point out an incorrect wiring diagram and difficulty getting it to work properly—or an inability to do so. One user reports that it works without any problems. However, the incorrect wiring instructions are said to pose a risk to the boiler, and in some cases the thermostat did not work or burned out.

Reviews by our members

  • I come to confirm what the others have commented. Either the design is wrong, or the construction of the board. The solenoid valve only opens and closes with the switch, which is connected backwards (it opens in the cold and closes in the warm) and the thermostat does not open or close the circuit. Two different technicians tried the installation and in the end they burned both thermostats. Of course, the company did not accept the return or admit that there is a mistake, while completely ignoring my comments. In the end, a Siemens was purchased and connected without any problem. Money wasted...

    Translated from Greek ·
    Did you find this review helpful?
  • DIMITRIS_KARAPETSAS
    1
    2 out of 3 members found this review helpful

    Verified purchase

    It works correctly but the design for the connection was wrong.... It could create or even burn the boiler. I spoke with the company that manufactured it and they confirmed to me that the image of the design was wrong in that specific batch. The neutral wire had to be connected to a different contact than the one shown in the design (Exactly the same problem. No relation to the automatic one I requested) I asked for image number 1 and I received image number 2

    Translated from Greek ·
    Did you find this review helpful?
  • Konstantinos_L95
    1
    1 out of 1 members found this review helpful

    Verified purchase

    The technician couldn't connect it, he said it has some damage, I'm not an expert, I'm just transferring knowledge from someone I trust.

    Translated from Greek ·
    Did you find this review helpful?
  • iwannabeu
    3
    2 out of 3 members found this review helpful

    Verified purchase

    It works correctly, but the design for the connection was wrong.... It could create or even burn the boiler. I spoke with the company that manufactured it and they confirmed to me that the image of the design was wrong in that specific batch. The neutral should have been connected to a different contact than the one shown in the design

    Translated from Greek ·
    Did you find this review helpful?
  • 5
    0 out of 2 members found this review helpful

    Verified purchase

    It works perfectly without any problem

    Translated from Greek ·
    Did you find this review helpful?
  • I come to confirm what the others have commented. Either the design is wrong, or the construction of the board. The solenoid valve only opens and closes with the switch, which is connected backwards (it opens in the cold and closes in the warm) and the thermostat does not open or close the circuit. Two different technicians tried the installation and in the end they burned both thermostats. Of course, the company did not accept the return or admit that there is a mistake, while completely ignoring my comments. In the end, a Siemens was purchased and connected without any problem. Money wasted...

    Translated from Greek ·
    0
  • It works correctly but the design for the connection was wrong.... It could create or even burn the boiler. I spoke with the company that manufactured it and they confirmed to me that the image of the design was wrong in that specific batch. The neutral wire had to be connected to a different contact than the one shown in the design (Exactly the same problem. No relation to the automatic one I requested) I asked for image number 1 and I received image number 2

    Translated from Greek ·
    2
  • The technician couldn't connect it, he said it has some damage, I'm not an expert, I'm just transferring knowledge from someone I trust.

    Translated from Greek ·
    1
  • It works correctly, but the design for the connection was wrong.... It could create or even burn the boiler. I spoke with the company that manufactured it and they confirmed to me that the image of the design was wrong in that specific batch. The neutral should have been connected to a different contact than the one shown in the design

    Translated from Greek ·
    2
  • It works perfectly without any problem

    Translated from Greek ·
    0
  • See all

Description & Specifications

The Eurolamp 147-44001 analog room thermostat regulates the temperature within a range of 0 to 40 °C. It is wall-mounted, mains-powered and features a switch, with NO and NC contacts.

  • Type: Analog
  • Installation: Wall-mounted
  • Programming: Non-programmable
  • Power supply: Mains
  • Supply voltage: 220–250 V
  • Operating frequency: 50/60 Hz
  • Rated power: 2 kW
  • Current: 4 A
  • Temperature range: 0–40 °C
  • Temperature increment: 2.5 °C
  • Thermostat contacts: NO and NC
  • Connection: Terminal block
  • Switch: Yes
  • Colour: White
  • Material: UL 94 V-0 flame-retardant
  • Ingress protection rating: IP20
  • Operating temperature: −10 to 50 °C
  • Width: 7.5 cm
  • Height: 7.5 cm
  • Depth: 3 cm

Manufacturer

Product Number
147-44001

Dimensions

Type
Analog
Placement
Wall-mounted
Power Source
Electric Power
Width
7.5 cm
Height
7.5 cm
Length
3 cm

Features & Functions

Touch Screen
No
Smart
No
Cooling-Heating
No
Temperature Range
0 - 40 °C
Programming
Non-Programmable
Temperature Gradation
2.5 °C

Wireless Attributes

Wi-Fi
No
Bluetooth
No
ZigBee
No
Z-Wave
No
RF
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

Reviews (5)

  1. 1
  2. 4 stars
    0
  3. 1
  4. 2 stars
    0
  5. 3
Review this product

What do users say? AI-generated summary

The overall picture is negative: although one user says it works normally, reviewers repeatedly point out an incorrect wiring diagram and difficulty getting it to work properly—or an inability to do so. One user reports that it works without any problems. However, the incorrect wiring instructions are said to pose a risk to the boiler, and in some cases the thermostat did not work or burned out.

Reviews by our members

  • I come to confirm what the others have commented. Either the design is wrong, or the construction of the board. The solenoid valve only opens and closes with the switch, which is connected backwards (it opens in the cold and closes in the warm) and the thermostat does not open or close the circuit. Two different technicians tried the installation and in the end they burned both thermostats. Of course, the company did not accept the return or admit that there is a mistake, while completely ignoring my comments. In the end, a Siemens was purchased and connected without any problem. Money wasted...

    Translated from Greek ·
    Did you find this review helpful?
  • DIMITRIS_KARAPETSAS
    1
    2 out of 3 members found this review helpful

    Verified purchase

    It works correctly but the design for the connection was wrong.... It could create or even burn the boiler. I spoke with the company that manufactured it and they confirmed to me that the image of the design was wrong in that specific batch. The neutral wire had to be connected to a different contact than the one shown in the design (Exactly the same problem. No relation to the automatic one I requested) I asked for image number 1 and I received image number 2

    Translated from Greek ·
    Did you find this review helpful?
  • Konstantinos_L95
    1
    1 out of 1 members found this review helpful

    Verified purchase

    The technician couldn't connect it, he said it has some damage, I'm not an expert, I'm just transferring knowledge from someone I trust.

    Translated from Greek ·
    Did you find this review helpful?
  • iwannabeu
    3
    2 out of 3 members found this review helpful

    Verified purchase

    It works correctly, but the design for the connection was wrong.... It could create or even burn the boiler. I spoke with the company that manufactured it and they confirmed to me that the image of the design was wrong in that specific batch. The neutral should have been connected to a different contact than the one shown in the design

    Translated from Greek ·
    Did you find this review helpful?
  • 5
    0 out of 2 members found this review helpful

    Verified purchase

    It works perfectly without any problem

    Translated from Greek ·
    Did you find this review helpful?
  • I come to confirm what the others have commented. Either the design is wrong, or the construction of the board. The solenoid valve only opens and closes with the switch, which is connected backwards (it opens in the cold and closes in the warm) and the thermostat does not open or close the circuit. Two different technicians tried the installation and in the end they burned both thermostats. Of course, the company did not accept the return or admit that there is a mistake, while completely ignoring my comments. In the end, a Siemens was purchased and connected without any problem. Money wasted...

    Translated from Greek ·
    0
  • It works correctly but the design for the connection was wrong.... It could create or even burn the boiler. I spoke with the company that manufactured it and they confirmed to me that the image of the design was wrong in that specific batch. The neutral wire had to be connected to a different contact than the one shown in the design (Exactly the same problem. No relation to the automatic one I requested) I asked for image number 1 and I received image number 2

    Translated from Greek ·
    2
  • The technician couldn't connect it, he said it has some damage, I'm not an expert, I'm just transferring knowledge from someone I trust.

    Translated from Greek ·
    1
  • It works correctly, but the design for the connection was wrong.... It could create or even burn the boiler. I spoke with the company that manufactured it and they confirmed to me that the image of the design was wrong in that specific batch. The neutral should have been connected to a different contact than the one shown in the design

    Translated from Greek ·
    2
  • It works perfectly without any problem

    Translated from Greek ·
    0
  • See all
12,78 €
14,00 €   shipping cost