Infant Oximetry Sensor, silicone, reusable for the Bluetooth Finger Oximeter with Temperature Sensor AM-806B with a cable length of 28cm. The sensor is suitable for use when non-invasive oxygen...

Infant Oximetry Sensor, silicone, reusable for the Bluetooth Finger Oximeter with Temperature Sensor AM-806B with a cable length of 28cm. The sensor is suitable for use when non-invasive oxygen saturation and arterial pulse rate determination is required for infant patients weighing 4-15kg.

The sensor is contraindicated for use on active patients, in motion...

See full description See full description
47 30
Delivery by Wed, 09 Sep
14,00 €   shipping cost
Sent from Greece
From Medical
Greece
13 pieces
See Medical Equipment on the page of Medical

Learn more about invoicing

Description

Description

Infant Oximetry Sensor, silicone, reusable for the Bluetooth Finger Oximeter with Temperature Sensor AM-806B with a cable length of 28cm. The sensor is suitable for use when non-invasive oxygen saturation and arterial pulse rate determination is required for infant patients weighing 4-15kg.

The sensor is contraindicated for use on active patients, in motion conditions, or for prolonged use. It must be moved every 4 hours (or more frequently if indicated by circulation status and/or skin integrity) and reapplied at a different site.

Sensor Features:

  • Wavelength: Red approximately 660nm - Infrared approximately 905nm
  • Output Power: The total optical output power of the LED sensor is less than 15mW.
  • Oxygen Saturation: Accuracy range 70-100% SpO2: ±3 digits
  • Pulse Accuracy Range: 20-250 BPM ±3 digits
  • Application: Infant Use 4-15kg

Manufacturer

See full description

Specifications

Specifications

Product Number
SO162ES
Type
Oximetry Sensor

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Infant Oximetry Sensor, silicone, reusable for the Bluetooth Finger Oximeter with Temperature Sensor AM-806B with a cable length of 28cm. The sensor is suitable for use when non-invasive oxygen saturation and arterial pulse rate determination is required for infant patients weighing 4-15kg.

The sensor is contraindicated for use on active patients, in motion conditions, or for prolonged use. It must be moved every 4 hours (or more frequently if indicated by circulation status and/or skin integrity) and reapplied at a different site.

Sensor Features:

  • Wavelength: Red approximately 660nm - Infrared approximately 905nm
  • Output Power: The total optical output power of the LED sensor is less than 15mW.
  • Oxygen Saturation: Accuracy range 70-100% SpO2: ±3 digits
  • Pulse Accuracy Range: 20-250 BPM ±3 digits
  • Application: Infant Use 4-15kg

Manufacturer

Product Number
SO162ES
Type
Oximetry Sensor