Industrial Switches

Abb Industrial Thermomagnetic Θερμομαγνητικός Διακόπτης 1.60-2.5A MS116-2.5 17933

The ABB MS116-2.5 thermal-magnetic motor circuit breaker switches motors on and off and protects them against short circuits, overloads, and phase failures, without requiring a fuse. The motor’s rated...

The ABB MS116-2.5 thermal-magnetic motor circuit breaker switches motors on and off and protects them against short circuits, overloads, and phase failures, without requiring a fuse. The motor’s rated current is adjusted using a dial on the device. It is suitable for three-phase and single-phase applications.

  • Type: Manual thermal-magnetic motor circuit...
See full description See full description
34 62 €
Delivery by Tue, 01 Dec
14,00 €   shipping cost
Sent from Greece
From Fotismos 5.0 (3)

Learn more about invoicing

Description

Description

The ABB MS116-2.5 thermal-magnetic motor circuit breaker switches motors on and off and protects them against short circuits, overloads, and phase failures, without requiring a fuse. The motor’s rated current is adjusted using a dial on the device. It is suitable for three-phase and single-phase applications.

  • Type: Manual thermal-magnetic motor circuit breaker
  • Current setting range: 1.60–2.50 A
  • Rated operational current: 2.5 A
  • Instantaneous short-circuit current setting: 31.3 A
  • Rated operational voltage: 690 V AC
  • Rated operational power, AC-3: 0.75 kW at 400 V, three-phase
  • Number of poles: 3
  • Rated impulse withstand voltage: 6 kV
  • Rated insulation voltage: 690 V
  • Trip class: 10A
  • Short-circuit breaking capacity, Ics: 50 kA at 230 V AC and 400 V AC, 10 kA at 440 V AC and 500 V AC, 5 kA at 690 V AC
  • Ultimate short-circuit breaking capacity, Icu: 75 kA at 230 V AC and 400 V AC, 30 kA at 440 V AC, 20 kA at 500 V AC, 10 kA at 690 V AC
  • Electrical endurance: 100,000 cycles
  • Mechanical endurance: 100,000 cycles

Manufacturer

See full description

Description

The ABB MS116-2.5 thermal-magnetic motor circuit breaker switches motors on and off and protects them against short circuits, overloads, and phase failures, without requiring a fuse. The motor’s rated current is adjusted using a dial on the device. It is suitable for three-phase and single-phase applications.

  • Type: Manual thermal-magnetic motor circuit breaker
  • Current setting range: 1.60–2.50 A
  • Rated operational current: 2.5 A
  • Instantaneous short-circuit current setting: 31.3 A
  • Rated operational voltage: 690 V AC
  • Rated operational power, AC-3: 0.75 kW at 400 V, three-phase
  • Number of poles: 3
  • Rated impulse withstand voltage: 6 kV
  • Rated insulation voltage: 690 V
  • Trip class: 10A
  • Short-circuit breaking capacity, Ics: 50 kA at 230 V AC and 400 V AC, 10 kA at 440 V AC and 500 V AC, 5 kA at 690 V AC
  • Ultimate short-circuit breaking capacity, Icu: 75 kA at 230 V AC and 400 V AC, 30 kA at 440 V AC, 20 kA at 500 V AC, 10 kA at 690 V AC
  • Electrical endurance: 100,000 cycles
  • Mechanical endurance: 100,000 cycles

Manufacturer

Abb - Industrial Switches Abb