Water Quality Meters

Hanna DiST 6 EC TDS Water Quality Meter with TDS EC Temperature Measurement Capability

The durable design and convenient size make it easy to carry and user-friendly.

Its advanced technology helps the user to calibrate very quickly.

Ideal for measuring water from wells, in greenhouses,...

The durable design and convenient size make it easy to carry and user-friendly.

Its advanced technology helps the user to calibrate very quickly.

Ideal for measuring water from wells, in greenhouses, in wastewater, boiler water, ship tanks, etc.

See full description See full description

Description

Description

The durable design and convenient size make it easy to carry and user-friendly.

Its advanced technology helps the user to calibrate very quickly.

Ideal for measuring water from wells, in greenhouses, in wastewater, boiler water, ship tanks, etc.

Main Benefits:

  • Water-resistant. Can withstand temporary exposure to water but should not be submerged or washed under running water.
  • Measurement of Conductivity (EC) and Total Dissolved Solids (TDS)
  • Automatic calibration and temperature compensation
  • Replaceable electrodes

Key Features:

  • Dual-level display for simultaneous readings
  • Easy to use
  • Durable packaging that floats in water
  • Direct contact temperature sensor
  • Replaceable electrode
  • Removable safety cap
  • Automatic temperature compensation
  • HOLD button for 'freezing' the screen
  • Battery level indicator

Specifications

  • Conductivity Range: 0.00 to 20 mS/cm
  • Conductivity Resolution: 0.01 mS/cm
  • Conductivity Accuracy: 2% F.S.
  • TDS Range: 0 to 10 ppt (g/L)
  • TDS Resolution: 0.01 ppm (g/L)
  • TDS Accuracy: 2% F.S.
  • Temperature Range: 0.0 to 60.0 C / 32.0 to 140.0 F
  • Temperature Resolution: 0.1 C / 0.1F
  • Temperature Accuracy: 0.5 C /1F
  • EC/TDS Calibration: Automatic, 1 point 12.88 mS/cm, 6.4 ppm (mg/L)
  • Temperature Compensation: Automatic, with β adjustable from 0.0 to 2.4% / °C
  • Conversion Factor: 0.45 to 1.00
  • Battery Type / Life: 1.5V (4) / approximately 100 hours of continuous use / Auto-off after 8 minutes of inactivity
  • Electrode/Sensor: HI73311 replaceable graphite EC/TDS electrode (included)
  • Environmental Conditions: 0 to 50°C (32 to 122°F); RH max 100%
  • Dimensions: 163 x 40 x 26 mm
  • Weight: 100 g

Manufacturer

See full description

Specifications

Specifications

Dimensions

Digital
Yes
Calibration Capability
No
ATC
-
Photometer Type
-

Measurement Capability

TDS
Yes
EC
Yes
pH
No
Temperature
Yes
ORP
No
Salinity
-
Hardness
-

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The durable design and convenient size make it easy to carry and user-friendly.

Its advanced technology helps the user to calibrate very quickly.

Ideal for measuring water from wells, in greenhouses, in wastewater, boiler water, ship tanks, etc.

Main Benefits:

  • Water-resistant. Can withstand temporary exposure to water but should not be submerged or washed under running water.
  • Measurement of Conductivity (EC) and Total Dissolved Solids (TDS)
  • Automatic calibration and temperature compensation
  • Replaceable electrodes

Key Features:

  • Dual-level display for simultaneous readings
  • Easy to use
  • Durable packaging that floats in water
  • Direct contact temperature sensor
  • Replaceable electrode
  • Removable safety cap
  • Automatic temperature compensation
  • HOLD button for 'freezing' the screen
  • Battery level indicator

Specifications

  • Conductivity Range: 0.00 to 20 mS/cm
  • Conductivity Resolution: 0.01 mS/cm
  • Conductivity Accuracy: 2% F.S.
  • TDS Range: 0 to 10 ppt (g/L)
  • TDS Resolution: 0.01 ppm (g/L)
  • TDS Accuracy: 2% F.S.
  • Temperature Range: 0.0 to 60.0 C / 32.0 to 140.0 F
  • Temperature Resolution: 0.1 C / 0.1F
  • Temperature Accuracy: 0.5 C /1F
  • EC/TDS Calibration: Automatic, 1 point 12.88 mS/cm, 6.4 ppm (mg/L)
  • Temperature Compensation: Automatic, with β adjustable from 0.0 to 2.4% / °C
  • Conversion Factor: 0.45 to 1.00
  • Battery Type / Life: 1.5V (4) / approximately 100 hours of continuous use / Auto-off after 8 minutes of inactivity
  • Electrode/Sensor: HI73311 replaceable graphite EC/TDS electrode (included)
  • Environmental Conditions: 0 to 50°C (32 to 122°F); RH max 100%
  • Dimensions: 163 x 40 x 26 mm
  • Weight: 100 g

Manufacturer

Dimensions

Digital
Yes
Calibration Capability
No
ATC
-
Photometer Type
-

Measurement Capability

TDS
Yes
EC
Yes
pH
No
Temperature
Yes
ORP
No
Salinity
-
Hardness
-

Important information