Legrand DX3 Phase 2-Pole Earth Leakage Relay 16A 30mA

Residual current circuit breaker 2P 16A C 0.03A type AC P312 - 411013

  • Double pole switch 230 V G
  • Rated residual current: 30 mA
  • Rated current: 16 A
  • Width in units 17.5 mm: 2
  • Mounting on TH35 bracket
  • ...

Residual current circuit breaker 2P 16A C 0.03A type AC P312 - 411013

  • Double pole switch 230 V G
  • Rated residual current: 30 mA
  • Rated current: 16 A
  • Width in units 17.5 mm: 2
  • Mounting on TH35 bracket
  • Connection option with comb or pin rails
  • Can be equipped with auxiliary contacts, trigger mechanisms, and drive units from the DX3 series
  • Gray activation lever
  • ...
See full description See full description

Description

Description

Residual current circuit breaker 2P 16A C 0.03A type AC P312 - 411013

  • Double pole switch 230 V G
  • Rated residual current: 30 mA
  • Rated current: 16 A
  • Width in units 17.5 mm: 2
  • Mounting on TH35 bracket
  • Connection option with comb or pin rails
  • Can be equipped with auxiliary contacts, trigger mechanisms, and drive units from the DX3 series
  • Gray activation lever
  • Type AC: Detects alternating sinusoidal residual currents
  • Rated short-circuit breaking capacity: 6000 A according to IEC 61009-1
  • 230 V~10 kA according to IEC 60947-2
  • Compatible with HX3 Optimal Energy Distribution System up to 125 A

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Number of Poles
2
Nominal Voltage
16 A
Ρεύμα Διαρροής
30 mA
Type of Residual Current Relay
Type AC

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Residual current circuit breaker 2P 16A C 0.03A type AC P312 - 411013

  • Double pole switch 230 V G
  • Rated residual current: 30 mA
  • Rated current: 16 A
  • Width in units 17.5 mm: 2
  • Mounting on TH35 bracket
  • Connection option with comb or pin rails
  • Can be equipped with auxiliary contacts, trigger mechanisms, and drive units from the DX3 series
  • Gray activation lever
  • Type AC: Detects alternating sinusoidal residual currents
  • Rated short-circuit breaking capacity: 6000 A according to IEC 61009-1
  • 230 V~10 kA according to IEC 60947-2
  • Compatible with HX3 Optimal Energy Distribution System up to 125 A

Manufacturer

Type
Earth Leakage
Number of Poles
2
Nominal Voltage
16 A
Ρεύμα Διαρροής
30 mA
Type of Residual Current Relay
Type AC

Important information