Industrial Switches

Hager X160 Industrial Automatic Power Αυτόματος Διακόπτης Ισχύος 25kΑ 3P 160Α Ρυθμιζόμενος HHA160H

The Hager X160 circuit breaker has a rated current of 160 A and a breaking capacity of 25 kA. The thermal trip can be set to 0.63, 0.8 and 1, and the trip type is TM.

  • Type: Circuit breaker
  • Poles:...

The Hager X160 circuit breaker has a rated current of 160 A and a breaking capacity of 25 kA. The thermal trip can be set to 0.63, 0.8 and 1, and the trip type is TM.

  • Type: Circuit breaker
  • Poles: 3P3D
  • Rated current: 160 A
  • Breaking capacity: 25 kA
  • Rated operational voltage (AC): 220/415 V
  • Rated insulation voltage: 690 V
  • Impulse withstand voltage: 8 kV
  • Rated...
See full description See full description
176 06 €
Lowest price '26
Delivery Fri, 11 Dec - Thu, 17 Dec
14,00 €   shipping cost
Sent from Greece
From Papantoniou 4.6 (31)

Learn more about invoicing

Description

Description

The Hager X160 circuit breaker has a rated current of 160 A and a breaking capacity of 25 kA. The thermal trip can be set to 0.63, 0.8 and 1, and the trip type is TM.

  • Type: Circuit breaker
  • Poles: 3P3D
  • Rated current: 160 A
  • Breaking capacity: 25 kA
  • Rated operational voltage (AC): 220/415 V
  • Rated insulation voltage: 690 V
  • Impulse withstand voltage: 8 kV
  • Rated frequency: 50/60 Hz
  • Thermal trip setting: 0.63/0.8/1
  • Trip type: TM
  • Modules: 4.5
  • Operating temperature: -25 to 70 °C
  • Storage temperature: -35 to 70 °C
  • Connection type: Screw connection
  • Stranded conductors: 4 / 70 mm²
  • Solid conductors: 4 / 95 mm²
  • Mechanical endurance: 4000 cycles
  • Electrical endurance: 1000 cycles
  • Total power loss at rated current: 43.8 W
  • Power loss per pole at rated current: 14.6 W
  • Tightening torque: 6 Nm
  • Rated short-circuit breaking capacity according to IEC 947.2 at 50 Hz: 80%

Manufacturer

See full description

Description

The Hager X160 circuit breaker has a rated current of 160 A and a breaking capacity of 25 kA. The thermal trip can be set to 0.63, 0.8 and 1, and the trip type is TM.

  • Type: Circuit breaker
  • Poles: 3P3D
  • Rated current: 160 A
  • Breaking capacity: 25 kA
  • Rated operational voltage (AC): 220/415 V
  • Rated insulation voltage: 690 V
  • Impulse withstand voltage: 8 kV
  • Rated frequency: 50/60 Hz
  • Thermal trip setting: 0.63/0.8/1
  • Trip type: TM
  • Modules: 4.5
  • Operating temperature: -25 to 70 °C
  • Storage temperature: -35 to 70 °C
  • Connection type: Screw connection
  • Stranded conductors: 4 / 70 mm²
  • Solid conductors: 4 / 95 mm²
  • Mechanical endurance: 4000 cycles
  • Electrical endurance: 1000 cycles
  • Total power loss at rated current: 43.8 W
  • Power loss per pole at rated current: 14.6 W
  • Tightening torque: 6 Nm
  • Rated short-circuit breaking capacity according to IEC 947.2 at 50 Hz: 80%