Automatic Circuit Breaker

Hager Automatic Circuit Breaker 16A Triple-pole AC NDN316A

Hager Automatic Circuit Breaker 10kA D 16A 3P NDN316A

The Hager Automatic Circuit Breaker 10kA D 16A 3P NDN316A offers reliable protection and performance for electrical circuits.

  • Nominal current:...

Hager Automatic Circuit Breaker 10kA D 16A 3P NDN316A

The Hager Automatic Circuit Breaker 10kA D 16A 3P NDN316A offers reliable protection and performance for electrical circuits.

  • Nominal current: 16A
  • Poles: 3P
  • Curve: D
  • Nominal voltage: 400V AC
  • Nominal short-circuit breaking capacity at 230V AC: 10kA
  • Impulse withstand voltage: 6000V
  • Protection index: IP20
  • ...
See full description See full description

Description

Description

Hager Automatic Circuit Breaker 10kA D 16A 3P NDN316A

The Hager Automatic Circuit Breaker 10kA D 16A 3P NDN316A offers reliable protection and performance for electrical circuits.

  • Nominal current: 16A
  • Poles: 3P
  • Curve: D
  • Nominal voltage: 400V AC
  • Nominal short-circuit breaking capacity at 230V AC: 10kA
  • Impulse withstand voltage: 6000V
  • Protection index: IP20
  • Electrical endurance in operating cycles: 4000
  • Number of mechanical operations: 20000
  • Integrated label holder
  • Cable connection cross-section at the output with screw, for stranded cable: 1 / 25 mm²
  • Cable connection cross-section at the output with screw, for single-core cable: 1 / 35 mm²
  • Standard: EN 60898-1, IEC 60947-2
  • Operating temperature: -25…70 °C
  • Dimensions: Height: 83mm, Width: 52.50mm, Depth: 70mm

Manufacturer

See full description

Specifications

Specifications

Specifications

Number of Poles
3
Rated Current
16 A
Operating Curve
Curve D

Power Supply

AC
Yes
DC
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Hager Automatic Circuit Breaker 10kA D 16A 3P NDN316A

The Hager Automatic Circuit Breaker 10kA D 16A 3P NDN316A offers reliable protection and performance for electrical circuits.

  • Nominal current: 16A
  • Poles: 3P
  • Curve: D
  • Nominal voltage: 400V AC
  • Nominal short-circuit breaking capacity at 230V AC: 10kA
  • Impulse withstand voltage: 6000V
  • Protection index: IP20
  • Electrical endurance in operating cycles: 4000
  • Number of mechanical operations: 20000
  • Integrated label holder
  • Cable connection cross-section at the output with screw, for stranded cable: 1 / 25 mm²
  • Cable connection cross-section at the output with screw, for single-core cable: 1 / 35 mm²
  • Standard: EN 60898-1, IEC 60947-2
  • Operating temperature: -25…70 °C
  • Dimensions: Height: 83mm, Width: 52.50mm, Depth: 70mm

Manufacturer

Specifications

Number of Poles
3
Rated Current
16 A
Operating Curve
Curve D

Power Supply

AC
Yes
DC
No