Phase Relays

Schneider Electric Acti 9 iID Phase 4-Pole Earth Leakage Relay 40A 30mA

4P 40A 30mA Type A Earth Leakage Relay A9R21440 for protection against electric shock and fire hazards due to current leakage.

  • Rated current: 40A
  • Rated voltage: 380...415 V AC
  • Frequency: 50/60 Hz
  • ...

4P 40A 30mA Type A Earth Leakage Relay A9R21440 for protection against electric shock and fire hazards due to current leakage.

  • Rated current: 40A
  • Rated voltage: 380...415 V AC
  • Frequency: 50/60 Hz
  • Number of poles: 4P
  • Rated impulse withstand voltage: 6 kV
  • Leakage sensitivity to earth: 30mA
  • Operating temperature: -25…60 °C
  • Earth leakage protection category:...
See full description See full description

Description

Description

4P 40A 30mA Type A Earth Leakage Relay A9R21440 for protection against electric shock and fire hazards due to current leakage.

  • Rated current: 40A
  • Rated voltage: 380...415 V AC
  • Frequency: 50/60 Hz
  • Number of poles: 4P
  • Rated impulse withstand voltage: 6 kV
  • Leakage sensitivity to earth: 30mA
  • Operating temperature: -25…60 °C
  • Earth leakage protection category: Type A
  • Neutral position: Left
  • Connections - terminals:
    • Single terminal top or bottom 1…35 mm² rigid
    • Single terminal top or bottom 1…25 mm² flexible
    • Single terminal top or bottom 1…25 mm² flexible with lug
  • Stripping length of wires: 214 mm for top or bottom connection
  • Electrical endurance: 21AC-1: Electrical endurance 2115000 cycles
  • Dimensions:
    • Height: 91mm
    • Width: 72mm
    • Depth: 73.5mm

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Number of Poles
4
Nominal Voltage
40 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

4P 40A 30mA Type A Earth Leakage Relay A9R21440 for protection against electric shock and fire hazards due to current leakage.

  • Rated current: 40A
  • Rated voltage: 380...415 V AC
  • Frequency: 50/60 Hz
  • Number of poles: 4P
  • Rated impulse withstand voltage: 6 kV
  • Leakage sensitivity to earth: 30mA
  • Operating temperature: -25…60 °C
  • Earth leakage protection category: Type A
  • Neutral position: Left
  • Connections - terminals:
    • Single terminal top or bottom 1…35 mm² rigid
    • Single terminal top or bottom 1…25 mm² flexible
    • Single terminal top or bottom 1…25 mm² flexible with lug
  • Stripping length of wires: 214 mm for top or bottom connection
  • Electrical endurance: 21AC-1: Electrical endurance 2115000 cycles
  • Dimensions:
    • Height: 91mm
    • Width: 72mm
    • Depth: 73.5mm

Manufacturer

Type
Earth Leakage
Number of Poles
4
Nominal Voltage
40 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A