The Yato YT-73092 is a professional LED clamp meter equipped with measurement clamps that allow the measurement of alternating current intensity in a single conductor using the induction method. As a result, it allows you to measure much higher current than conventional electrical meters. It also allows you to measure AC and DC voltage, resistance, and check the operation of diodes. This is useful for detecting faulty components in electrical installations
Features:
- Low resistance voltage measurement function
- Overload protection
- Audio signal allows easy verification of circuit continuity
- Automatic power off function
- Backlit LCD display
- Measurement field clamp flashlight that facilitates measurement in low light
- Battery level indicator
- LCD display, maximum displayed result: 5999
- Acoustic signal in circuit continuity test for resistance below 60 Ω
- Diode and continuity tests can be activated separately
- Clamps open up to 26 mm and allow measurement of a single conductor with a maximum diameter of 18 mm
- Construction with overload protection
- Automatic meter power off after 15 minutes of inactivity
- Low battery indicator
- Power supply: two 1.5V batteries (AAA).
Technical Specifications:
- Maximum diameter of measured conductor: 18 mm
- Automatic measurement range adjustment
- AC voltage measurement: A.C. 0-600V, TRUE RMS + V.F.C. + LowZ
- DC voltage measurement: D.C. 0-600V, LowZ
- Alternating current measurement: A.C. 0-600A, TRUE RMS + V.F.C.
- Variable frequency voltage measurement
- Resistance measurement: 0-60MΩ
- Diode test: IF 1mA, UR 2.3V
- Continuity test: 0-120Ω
- Sampling rate: 2.5-3 times/second.
Includes: 2 test leads and a cover
Integrated functions
- TRUE RMS - a meter with this function calculates the true value of AC voltage and current for both sinusoidal and non-sinusoidal waveforms. The device first measures the true value of the sinusoidal wave at multiple time intervals → then squares the measurement results → adds them up → calculates the average value → and finally takes the square root of the mean result. The measurement result is a true RMS voltage/current, even for distorted sinusoidal or square waveforms.
- NCV - non-contact detection of alternating voltage using the induction method. The meter detects the presence of voltage in an insulated conductor, and can also indicate the phase of the conductor
- LowZ - AC and DC voltage measurement in low resistance mode. The phenomenon of ghost voltage can make it difficult to diagnose the electrical network, e.g. in industrial buildings. It consists of the appearance of voltage in an unconnected cable, where the voltage was caused by the cable that was connected to the network through the same channel.
- True RMS
- Yes
- with Test Leads
- No
- AC Current
- 600 A
- Indication
- Digital
- Bluetooth
- No
- Safety Category
- CAT II
Important information
Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.