Voltage Monitors

Tele Single Phase Voltage Monitor Rail 10A E1IM10AACL10

Voltage monitoring in single-phase network - ENYA series

  • Multi-purpose
  • Monitoring of low current intensity
  • Overload monitoring
  • Monitoring of the window between Min and Max
  • Overload monitoring with error...

Voltage monitoring in single-phase network - ENYA series

  • Multi-purpose
  • Monitoring of low current intensity
  • Overload monitoring
  • Monitoring of the window between Min and Max
  • Overload monitoring with error threshold
  • Low current monitoring with error threshold
  • Monitoring of the window between minimum and maximum with error protection
  • Compatible with power relays...
See full description See full description

Top specs

  • See all

Learn more about invoicing

Description

Description

Voltage monitoring in single-phase network - ENYA series

  • Multi-purpose
  • Monitoring of low current intensity
  • Overload monitoring
  • Monitoring of the window between Min and Max
  • Overload monitoring with error threshold
  • Low current monitoring with error threshold
  • Monitoring of the window between minimum and maximum with error protection
  • Compatible with power relays (electrons) that receive the final load

Input characteristics

  • Supply voltage = 230V AC
  • Tolerance: -15% to +15%
  • Terminals: L-N
  • Voltage drop: >20% of nominal voltage
  • Nominal overvoltage: 4kV
  • Overvoltage category: III (according to IEC 60664-1)

Output characteristics

  • Nominal voltage: 250V
  • 1 changeover contact (CO)
  • Switching capacity: 1250VA (5A/250V AC)
  • Activation delay adjustment: 0.1 to 10 adjustable

Technical Specifications

  • Nominal Voltage: 250V
  • Nominal Current: 5A
  • Operating Temperature: -25°C / +55°C
  • Mounting: DIN rail
  • Mounting/Connection Method: DIN rail
  • Number of DIN elements: 1
  • With Programming: Overload Control, Undercurrent
  • Type: Voltage Monitors
  • Main Contact Type: 1 CO
  • Programming Settings: 0.1s...10s


Manufacturer

See full description

Specifications

Specifications

Placement
Rail
Type
Single phase
Rated Contact Current
10 A
Digital
No
Protection Type
Overvoltage, Undervoltage, Overvoltage

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Voltage monitoring in single-phase network - ENYA series

  • Multi-purpose
  • Monitoring of low current intensity
  • Overload monitoring
  • Monitoring of the window between Min and Max
  • Overload monitoring with error threshold
  • Low current monitoring with error threshold
  • Monitoring of the window between minimum and maximum with error protection
  • Compatible with power relays (electrons) that receive the final load

Input characteristics

  • Supply voltage = 230V AC
  • Tolerance: -15% to +15%
  • Terminals: L-N
  • Voltage drop: >20% of nominal voltage
  • Nominal overvoltage: 4kV
  • Overvoltage category: III (according to IEC 60664-1)

Output characteristics

  • Nominal voltage: 250V
  • 1 changeover contact (CO)
  • Switching capacity: 1250VA (5A/250V AC)
  • Activation delay adjustment: 0.1 to 10 adjustable

Technical Specifications

  • Nominal Voltage: 250V
  • Nominal Current: 5A
  • Operating Temperature: -25°C / +55°C
  • Mounting: DIN rail
  • Mounting/Connection Method: DIN rail
  • Number of DIN elements: 1
  • With Programming: Overload Control, Undercurrent
  • Type: Voltage Monitors
  • Main Contact Type: 1 CO
  • Programming Settings: 0.1s...10s


Manufacturer

Placement
Rail
Type
Single phase
Rated Contact Current
10 A
Digital
No
Protection Type
Overvoltage, Undervoltage, Overvoltage

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

115,00 €
14,00 €   shipping cost