Phase Relays

Hager Phase Relay Earth Leakage 63A Four-Poles with Voltage 400V

Hager, RCCB Residual Current Switch 3P+N 63A 30mA 10kA F, CDF663D

  • Number of poles: 4 P
  • Configuration: 3P+N
  • Mounting: DIN rail
  • Contact position indication: yes
  • Fault indication: yes

Electrical...

Hager, RCCB Residual Current Switch 3P+N 63A 30mA 10kA F, CDF663D

  • Number of poles: 4 P
  • Configuration: 3P+N
  • Mounting: DIN rail
  • Contact position indication: yes
  • Fault indication: yes

Electrical characteristics

  • Rated operational voltage EU(AC): 230 / 400 V
  • Power supply voltage type: Alternating current
  • Frequency: 50 Hz
  • Rated insulation voltage Ui: 500 V
  • ...
See full description See full description

Learn more about invoicing

Description

Description

Hager, RCCB Residual Current Switch 3P+N 63A 30mA 10kA F, CDF663D

  • Number of poles: 4 P
  • Configuration: 3P+N
  • Mounting: DIN rail
  • Contact position indication: yes
  • Fault indication: yes

Electrical characteristics

  • Rated operational voltage EU(AC): 230 / 400 V
  • Power supply voltage type: Alternating current
  • Frequency: 50 Hz
  • Rated insulation voltage Ui: 500 V
  • Maximum operational voltage: 440 V
  • Rated impulse withstand voltage Uimp: 4000 V
  • Rated short-circuit current under conditions Inc according to PN-EN 61008-1: 10 kA
  • Total power loss for rated current: 9.29 W
  • Protection rating: IP20
  • Type of residual current device: F
  • Overvoltage resistance according to IEC 60947-3: 6000 V

Dimensions

  • Product depth: 70 mm
  • Product height: 85 mm
  • Product width: 72 mm

Assembly / Product mounting position

  • 360°: yes

Connection capacity

  • Output terminal capacity for a flexible cable (stranded): 1 / 16 mm²
  • Output terminal capacity for a rigid cable (wire): 1 / 25 mm²
  • Input terminal capacity for a rigid cable (wire): 1 / 25 mm²
  • Input terminal capacity for a flexible cable (stranded): 1 / 16 mm²
  • Quick connection equipment: no
  • Selectivity: no
  • Additional accessories: yes
  • Terminal cover: no
  • Transparent cover of the marking field: yes

Usage conditions

  • Pollution degree according to IEC 60664 / IEC 60947-2: 2
  • Mechanical resistance (number of cycles): 20000
  • Electrical resistance (number of cycles): 10000

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Number of Poles
4
Voltage
400 V
Nominal Voltage
63 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type F

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Hager, RCCB Residual Current Switch 3P+N 63A 30mA 10kA F, CDF663D

  • Number of poles: 4 P
  • Configuration: 3P+N
  • Mounting: DIN rail
  • Contact position indication: yes
  • Fault indication: yes

Electrical characteristics

  • Rated operational voltage EU(AC): 230 / 400 V
  • Power supply voltage type: Alternating current
  • Frequency: 50 Hz
  • Rated insulation voltage Ui: 500 V
  • Maximum operational voltage: 440 V
  • Rated impulse withstand voltage Uimp: 4000 V
  • Rated short-circuit current under conditions Inc according to PN-EN 61008-1: 10 kA
  • Total power loss for rated current: 9.29 W
  • Protection rating: IP20
  • Type of residual current device: F
  • Overvoltage resistance according to IEC 60947-3: 6000 V

Dimensions

  • Product depth: 70 mm
  • Product height: 85 mm
  • Product width: 72 mm

Assembly / Product mounting position

  • 360°: yes

Connection capacity

  • Output terminal capacity for a flexible cable (stranded): 1 / 16 mm²
  • Output terminal capacity for a rigid cable (wire): 1 / 25 mm²
  • Input terminal capacity for a rigid cable (wire): 1 / 25 mm²
  • Input terminal capacity for a flexible cable (stranded): 1 / 16 mm²
  • Quick connection equipment: no
  • Selectivity: no
  • Additional accessories: yes
  • Terminal cover: no
  • Transparent cover of the marking field: yes

Usage conditions

  • Pollution degree according to IEC 60664 / IEC 60947-2: 2
  • Mechanical resistance (number of cycles): 20000
  • Electrical resistance (number of cycles): 10000

Manufacturer

Type
Earth Leakage
Number of Poles
4
Voltage
400 V
Nominal Voltage
63 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type F

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.