Fire Alarms

Paradox Fighter MPR Fire Detection Panel

The Paradox Fighter MPR fire alarm panel combines conventional fire detection and extinguishing, with BUS communication and a three-level access menu. With expansion boards, the system supports 8 to...

The Paradox Fighter MPR fire alarm panel combines conventional fire detection and extinguishing, with BUS communication and a three-level access menu. With expansion boards, the system supports 8 to 72 zones and 8 to 72 relays, and can be configured with up to 18 extinguishing areas.

The keypad features an LCD and backlit alphanumeric keys, and up to 8...

See full description See full description
327 36 €
Delivery by Wed, 11 Nov
14,00 €   shipping cost
Sent from Greece
From Kalofolias 4.7 (8)

Learn more about invoicing

Description

Description

The Paradox Fighter MPR fire alarm panel combines conventional fire detection and extinguishing, with BUS communication and a three-level access menu. With expansion boards, the system supports 8 to 72 zones and 8 to 72 relays, and can be configured with up to 18 extinguishing areas.

The keypad features an LCD and backlit alphanumeric keys, and up to 8 keypads or display devices can be connected to the system. Features include Intellizone alarm verification, adjustable Day/Night mode, general evacuation, detector testing, and event logging. Monitoring, operation, and programming are supported via RS-232, while remote connection via TCP/IP requires an optional module.

  • Type: Conventional fire detection and extinguishing panel
  • Communication technology: 4-wire BUS
  • Access levels: 3
  • Zones: 8 to 72, with 8 zones per expansion board
  • Expansion relays: 8 to 72, with 8 relays per expansion board
  • Extinguishing areas: Up to 18
  • Zones and relays per extinguishing area: 4 zones and 4 relays
  • Keypad: With a 4 × 20-character LCD and backlit alphanumeric keypad
  • Display devices and keypads: Up to 8
  • Alarm outputs: 2 supervised, 24 VDC / 1 A maximum
  • Fault output: 1 unsupervised, dry relay contact, 3 A maximum
  • Zone relay outputs: Provide 24 VDC when the corresponding zone is in alarm
  • Expansion power supplies: Up to 16 FPS5 units
  • Central station communication: Via PSTN and Contact ID protocol
  • Communication port: RS-232
  • Remote connection: Via optional FRTCP/IP module
  • Event logging: Up to 1,000 events in internal memory
  • Certifications: EN 54-2:1997/A1:2006/AC:1999, EN 54-4:1997/A2:2006/A1:2002/AC:1999, and EN 12094-1:2003

Manufacturer

See full description

Specifications

Specifications

Type
Fire Detection Panel
Thread
No
Autonomous
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The Paradox Fighter MPR fire alarm panel combines conventional fire detection and extinguishing, with BUS communication and a three-level access menu. With expansion boards, the system supports 8 to 72 zones and 8 to 72 relays, and can be configured with up to 18 extinguishing areas.

The keypad features an LCD and backlit alphanumeric keys, and up to 8 keypads or display devices can be connected to the system. Features include Intellizone alarm verification, adjustable Day/Night mode, general evacuation, detector testing, and event logging. Monitoring, operation, and programming are supported via RS-232, while remote connection via TCP/IP requires an optional module.

  • Type: Conventional fire detection and extinguishing panel
  • Communication technology: 4-wire BUS
  • Access levels: 3
  • Zones: 8 to 72, with 8 zones per expansion board
  • Expansion relays: 8 to 72, with 8 relays per expansion board
  • Extinguishing areas: Up to 18
  • Zones and relays per extinguishing area: 4 zones and 4 relays
  • Keypad: With a 4 × 20-character LCD and backlit alphanumeric keypad
  • Display devices and keypads: Up to 8
  • Alarm outputs: 2 supervised, 24 VDC / 1 A maximum
  • Fault output: 1 unsupervised, dry relay contact, 3 A maximum
  • Zone relay outputs: Provide 24 VDC when the corresponding zone is in alarm
  • Expansion power supplies: Up to 16 FPS5 units
  • Central station communication: Via PSTN and Contact ID protocol
  • Communication port: RS-232
  • Remote connection: Via optional FRTCP/IP module
  • Event logging: Up to 1,000 events in internal memory
  • Certifications: EN 54-2:1997/A1:2006/AC:1999, EN 54-4:1997/A2:2006/A1:2002/AC:1999, and EN 12094-1:2003