Medical Consumables by Specialty

Bournas Medicals SMB TCu-380A Medical Consumable

SMB TCu-380A Spiral

An intrauterine contraceptive that is very effective and works as soon as it is placed.

The TCu 380A intrauterine device should be inserted and removed only by a specialized...

SMB TCu-380A Spiral

An intrauterine contraceptive that is very effective and works as soon as it is placed.

The TCu 380A intrauterine device should be inserted and removed only by a specialized gynecologist - physician.

  • Each T-shaped frame contains 176 11 mg of copper spiral wrapped around its vertical stem.
  • Copper collar approximately 68.7 3 mg of copper...
See full description See full description

Description

Description

SMB TCu-380A Spiral

An intrauterine contraceptive that is very effective and works as soon as it is placed.

The TCu 380A intrauterine device should be inserted and removed only by a specialized gynecologist - physician.

  • Each T-shaped frame contains 176 ± 11 mg of copper spiral wrapped around its vertical stem.
  • Copper collar approximately 68.7 ± 3 mg of copper on each transverse arm.
  • X-ray opaque with a single-strand HDPE thread attached to the base of the intrauterine device.
  • Total surface area of copper on the device is 380 mm² ± 23 mm².
  • Vertical length: 36 ± 0.5 mm.
  • Horizontal width: 32 ± 0.5 mm.
  • The TCu 380A can remain in place in the uterus for a maximum lifespan of 10 years.

Manufacturer

See full description

Specifications

Specifications

Medical Speciality
Gynecological
Quantity
1 pcs

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

SMB TCu-380A Spiral

An intrauterine contraceptive that is very effective and works as soon as it is placed.

The TCu 380A intrauterine device should be inserted and removed only by a specialized gynecologist - physician.

  • Each T-shaped frame contains 176 ± 11 mg of copper spiral wrapped around its vertical stem.
  • Copper collar approximately 68.7 ± 3 mg of copper on each transverse arm.
  • X-ray opaque with a single-strand HDPE thread attached to the base of the intrauterine device.
  • Total surface area of copper on the device is 380 mm² ± 23 mm².
  • Vertical length: 36 ± 0.5 mm.
  • Horizontal width: 32 ± 0.5 mm.
  • The TCu 380A can remain in place in the uterus for a maximum lifespan of 10 years.

Manufacturer

Medical Speciality
Gynecological
Quantity
1 pcs

Important information