Phase Relays

Autonics Phase 4-Pole Earth Leakage Relay 100A

Characteristics:

  • AC type leakage rail relay
  • The AC type has the ability to protect only
    from alternating sinusoidal current leaks
  • Specifications: IEC61008
  • Protection: current leakage
  • Rated currents: 100A
  • ...

Characteristics:

  • AC type leakage rail relay
  • The AC type has the ability to protect only
    from alternating sinusoidal current leaks
  • Specifications: IEC61008
  • Protection: current leakage
  • Rated currents: 100A
  • Rated voltage: 240/415VAC
  • Rated Residual Current IDN: 100mA
  • Disconnection Time: 0.5 x IDN < 0.1s
  • Number of poles: 4P(3+N)
  • Terminal capacity: up to 35mm
  • Width:...
See full description See full description

Description

Description

Characteristics:

  • AC type leakage rail relay
  • The AC type has the ability to protect only
    from alternating sinusoidal current leaks
  • Specifications: IEC61008
  • Protection: current leakage
  • Rated currents: 100A
  • Rated voltage: 240/415VAC
  • Rated Residual Current IDN: 100mA
  • Disconnection Time: 0.5 x IDN < 0.1s
  • Number of poles: 4P(3+N)
  • Terminal capacity: up to 35mm
  • Width: 18mm/pole
  • Rated Short-Circuit Current: 3000A
  • Installation: 35mm DIN rail

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Number of Poles
4
Nominal Voltage
100 A
Leakage Current
100 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type AC

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Characteristics:

  • AC type leakage rail relay
  • The AC type has the ability to protect only
    from alternating sinusoidal current leaks
  • Specifications: IEC61008
  • Protection: current leakage
  • Rated currents: 100A
  • Rated voltage: 240/415VAC
  • Rated Residual Current IDN: 100mA
  • Disconnection Time: 0.5 x IDN < 0.1s
  • Number of poles: 4P(3+N)
  • Terminal capacity: up to 35mm
  • Width: 18mm/pole
  • Rated Short-Circuit Current: 3000A
  • Installation: 35mm DIN rail

Manufacturer

Type
Earth Leakage
Number of Poles
4
Nominal Voltage
100 A
Leakage Current
100 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type AC

Important information