Thermal Magnetic Switch 4.0-6.3A 100kA MS132-6.3, also known as motor protection switch. It is used to activate and deactivate motors and to protect them from short circuits, overloads, and phase...

Thermal Magnetic Switch 4.0-6.3A 100kA MS132-6.3, also known as motor protection switch. It is used to activate and deactivate motors and to protect them from short circuits, overloads, and phase failures without the need for a fuse.

Features:

  • Nominal operating voltage main circuit: 690V AC / 250V DC
  • Nominal operating current: 6.3A
  • Nominal instantaneous...
See full description See full description

Description

Description

Thermal Magnetic Switch 4.0-6.3A 100kA MS132-6.3, also known as motor protection switch. It is used to activate and deactivate motors and to protect them from short circuits, overloads, and phase failures without the need for a fuse.

Features:

  • Nominal operating voltage main circuit: 690V AC / 250V DC
  • Nominal operating current: 6.3A
  • Nominal instantaneous short-circuit current setting: 78.8A
  • Adjustment range: 4.0 ... 6.3A
  • Nominal operational power AC-3 (P e): 2.2 kW (400 V) Three-phase
  • Nominal impulse withstand voltage (U imp): 6 kV
  • Nominal insulation voltage (U i): 690 V
  • Number of Poles: 3
  • Electrical endurance: 50000 cycles
  • Mechanical endurance: 100000 cycles
  • Nominal short-circuit breaking capacity (I cs): 100 kA (230 V AC), 100 kA (400 V AC), 30 kA (440 V AC), 20 kA (500 V AC), 3 kA (690 V AC)
  • Nominal ultimate short-circuit breaking capacity (I cu): 100 kA (230 V AC), 100 kA (400 V AC), 30 kA (440 V AC), 20 kA (500 V AC), 3 kA (690 V AC)

Manufacturer

See full description

Description

Thermal Magnetic Switch 4.0-6.3A 100kA MS132-6.3, also known as motor protection switch. It is used to activate and deactivate motors and to protect them from short circuits, overloads, and phase failures without the need for a fuse.

Features:

  • Nominal operating voltage main circuit: 690V AC / 250V DC
  • Nominal operating current: 6.3A
  • Nominal instantaneous short-circuit current setting: 78.8A
  • Adjustment range: 4.0 ... 6.3A
  • Nominal operational power AC-3 (P e): 2.2 kW (400 V) Three-phase
  • Nominal impulse withstand voltage (U imp): 6 kV
  • Nominal insulation voltage (U i): 690 V
  • Number of Poles: 3
  • Electrical endurance: 50000 cycles
  • Mechanical endurance: 100000 cycles
  • Nominal short-circuit breaking capacity (I cs): 100 kA (230 V AC), 100 kA (400 V AC), 30 kA (440 V AC), 20 kA (500 V AC), 3 kA (690 V AC)
  • Nominal ultimate short-circuit breaking capacity (I cu): 100 kA (230 V AC), 100 kA (400 V AC), 30 kA (440 V AC), 20 kA (500 V AC), 3 kA (690 V AC)

Manufacturer