Bentel Component for Fire Detection System 24 Zones

The Bentel FC410MIO module for a 24-zone fire detection system features three inputs and four low-power outputs. The inputs monitor external devices and can be configured to operate with normally open...

The Bentel FC410MIO module for a 24-zone fire detection system features three inputs and four low-power outputs. The inputs monitor external devices and can be configured to operate with normally open or normally closed contacts.

The four low-power outputs can drive a self-powered HVR800 high-voltage relay. When low-voltage outputs 3 and 4 are disabled,...

See full description See full description
163 68 €
Delivery by Wed, 11 Nov
14,00 €   shipping cost
Sent from Greece
From Kalofolias 4.7 (8)

Learn more about invoicing

Description

Description

The Bentel FC410MIO module for a 24-zone fire detection system features three inputs and four low-power outputs. The inputs monitor external devices and can be configured to operate with normally open or normally closed contacts.

The four low-power outputs can drive a self-powered HVR800 high-voltage relay. When low-voltage outputs 3 and 4 are disabled, outputs 1 and 2 operate as volt-free changeover relay contacts.

  • Number of zones: 24
  • Inputs: 3
  • Low-power outputs: 4
  • Changeover contacts: 2 A at 24 Vdc

Manufacturer

See full description

Specifications

Specifications

Thread
No
Autonomous
No
Zones Number
24

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The Bentel FC410MIO module for a 24-zone fire detection system features three inputs and four low-power outputs. The inputs monitor external devices and can be configured to operate with normally open or normally closed contacts.

The four low-power outputs can drive a self-powered HVR800 high-voltage relay. When low-voltage outputs 3 and 4 are disabled, outputs 1 and 2 operate as volt-free changeover relay contacts.

  • Number of zones: 24
  • Inputs: 3
  • Low-power outputs: 4
  • Changeover contacts: 2 A at 24 Vdc

Manufacturer

Thread
No
Autonomous
No
Zones Number
24

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.