Electrical Power Transformers

Atman TRF1500 Open Type Isolation Transformer 1500VA

The Atman TRF1500 isolation transformer is an open-type model with a power rating of 1500 VA. It supports a maximum primary voltage of 1000 V AC and a maximum secondary voltage of 500 V AC, while the...

The Atman TRF1500 isolation transformer is an open-type model with a power rating of 1500 VA. It supports a maximum primary voltage of 1000 V AC and a maximum secondary voltage of 500 V AC, while the isolation voltage is 3750 V AC at a primary voltage of 450 V.

  • Type: Open type
  • Kind: Isolation
  • Power rating: 1500 VA
  • Maximum primary voltage: 1000 V AC
  • Maximum...
See full description See full description
341 00 €
Delivery by Fri, 27 Nov
14,00 €   shipping cost
Sent from Greece
From Ledcity 4.9 (45)
Greece
20+ pieces
See Energy on the page of Ledcity

Learn more about invoicing

Description

Description

The Atman TRF1500 isolation transformer is an open-type model with a power rating of 1500 VA. It supports a maximum primary voltage of 1000 V AC and a maximum secondary voltage of 500 V AC, while the isolation voltage is 3750 V AC at a primary voltage of 450 V.

  • Type: Open type
  • Kind: Isolation
  • Power rating: 1500 VA
  • Maximum primary voltage: 1000 V AC
  • Maximum secondary voltage: 500 V AC
  • Isolation voltage: 3750 V AC at a primary voltage of 450 V
  • Protection class: I
  • Insulation class: B, F, H
  • Operation: Continuous
  • Cooling: Natural, air-cooled
  • Degree of protection: IP 00
  • Dimensions: 240 × 180 × 130 mm
  • Manufacturing standard: EN 61558
  • Compliance: CE, RoHS

Manufacturer

See full description

Specifications

Specifications

Type
Open Type
Type
Isolation
Power
1500 VA

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The Atman TRF1500 isolation transformer is an open-type model with a power rating of 1500 VA. It supports a maximum primary voltage of 1000 V AC and a maximum secondary voltage of 500 V AC, while the isolation voltage is 3750 V AC at a primary voltage of 450 V.

  • Type: Open type
  • Kind: Isolation
  • Power rating: 1500 VA
  • Maximum primary voltage: 1000 V AC
  • Maximum secondary voltage: 500 V AC
  • Isolation voltage: 3750 V AC at a primary voltage of 450 V
  • Protection class: I
  • Insulation class: B, F, H
  • Operation: Continuous
  • Cooling: Natural, air-cooled
  • Degree of protection: IP 00
  • Dimensions: 240 × 180 × 130 mm
  • Manufacturing standard: EN 61558
  • Compliance: CE, RoHS

Manufacturer

Type
Open Type
Type
Isolation
Power
1500 VA

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.