Phase Relays

Hager Phase Relay Earth Leakage 40A Four-Poles with Voltage 500V

Product Design Type: RCCB VI

Number of Poles: 4P

Installation: DIN Rail

Electrical Characteristics

  • Rated Operating Voltage Ue (AC): 230/400V
  • Rated Frequency: 50 Hz
  • Rated Insulation Voltage Ui: 500V
  • ...

Product Design Type: RCCB VI

Number of Poles: 4P

Installation: DIN Rail

Electrical Characteristics

  • Rated Operating Voltage Ue (AC): 230/400V
  • Rated Frequency: 50 Hz
  • Rated Insulation Voltage Ui: 500V
  • Rated Impulse Voltage Uimp: 4 kV
  • Rated Residual Current dI: 300 mA
  • Rated Discharging Current (in 8/20µs): 5 kA
  • Rated Breaking Capacity Im: 1.5 kA
  • Rated...
See full description See full description

Learn more about invoicing

Description

Description

Product Design Type: RCCB VI

Number of Poles: 4P

Installation: DIN Rail

Electrical Characteristics

  • Rated Operating Voltage Ue (AC): 230/400V
  • Rated Frequency: 50 Hz
  • Rated Insulation Voltage Ui: 500V
  • Rated Impulse Voltage Uimp: 4 kV
  • Rated Residual Current dI: 300 mA
  • Rated Discharging Current (in 8/20µs): 5 kA
  • Rated Breaking Capacity Im: 1.5 kA
  • Rated Short-Circuit Current Under Conditions Inc: 6 kA
  • Rated Current at -15°C: 40A
  • Rated Current at -20°C: 40A
  • Rated Current at 0°C: 40A
  • Rated Current at 10°C: 40A
  • Rated Current at -10°C: 40A
  • Rated Current at 15°C: 40A
  • Rated Current at 20°C: 40A
  • Rated Current at 25°C: 40A
  • Rated Current at -25°C: 40A
  • Rated Current at 30°C: 40A
  • Rated Current at 35°C: 40A
  • Rated Current at 40°C: 40A
  • Rated Current at 45°C: 40A
  • Rated Current at 5°C: 40A
  • Rated Current at -5°C: 40A
  • Rated Current at 50°C: 40A
  • Rated Current at 55°C: 40A
  • Rated Current at 60°C: 40A
  • Rated Current at 65°C: 40A
  • Rated Current at 70°C: 40A
  • Total Power Losses for Rated Current: 7.2W
  • Power Losses Per Pole for Rated Current: 2.1 W
  • Electrical Endurance (number of cycles): 2000
  • Mechanical Endurance (number of cycles): 4000

Dimensions

  • Product Depth: 70 mm
  • Product Height: 83 mm
  • Product Width: 70 mm

Installation / Assembly

  • Tightening Torque: 2.8 Nm
  • Cross-Section of Flexible Cable (cord) at Terminal: 16 mm²
  • Cross-Section of Rigid Conductor (wire) at Terminal: 25 mm²
  • Type of Connection: screw

Equipment

  • Additional Accessories: Yes

Standard

  • Standard: EN 61008-1
  • European RoHS Directive: compliant
  • European WEEE Directive: Yes

Safety

  • Degree of Protection: IP20
  • Type of Residual Current Switch: A
  • Pollution Degree according to IEC 60664 / IEC 60947-2: 2
  • Storage Temperature: -55 to 70 °C

Device Group Name: CP{Number of Poles} 4 . {Rated current [A]} 40 . {Tenderness} A . {Ingress Protection [IP]} IP20 . {Rated Residual Current [A]} 0.3

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Number of Poles
4
Voltage
500 V
Nominal Voltage
40 A
Leakage Current
300 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Product Design Type: RCCB VI

Number of Poles: 4P

Installation: DIN Rail

Electrical Characteristics

  • Rated Operating Voltage Ue (AC): 230/400V
  • Rated Frequency: 50 Hz
  • Rated Insulation Voltage Ui: 500V
  • Rated Impulse Voltage Uimp: 4 kV
  • Rated Residual Current dI: 300 mA
  • Rated Discharging Current (in 8/20µs): 5 kA
  • Rated Breaking Capacity Im: 1.5 kA
  • Rated Short-Circuit Current Under Conditions Inc: 6 kA
  • Rated Current at -15°C: 40A
  • Rated Current at -20°C: 40A
  • Rated Current at 0°C: 40A
  • Rated Current at 10°C: 40A
  • Rated Current at -10°C: 40A
  • Rated Current at 15°C: 40A
  • Rated Current at 20°C: 40A
  • Rated Current at 25°C: 40A
  • Rated Current at -25°C: 40A
  • Rated Current at 30°C: 40A
  • Rated Current at 35°C: 40A
  • Rated Current at 40°C: 40A
  • Rated Current at 45°C: 40A
  • Rated Current at 5°C: 40A
  • Rated Current at -5°C: 40A
  • Rated Current at 50°C: 40A
  • Rated Current at 55°C: 40A
  • Rated Current at 60°C: 40A
  • Rated Current at 65°C: 40A
  • Rated Current at 70°C: 40A
  • Total Power Losses for Rated Current: 7.2W
  • Power Losses Per Pole for Rated Current: 2.1 W
  • Electrical Endurance (number of cycles): 2000
  • Mechanical Endurance (number of cycles): 4000

Dimensions

  • Product Depth: 70 mm
  • Product Height: 83 mm
  • Product Width: 70 mm

Installation / Assembly

  • Tightening Torque: 2.8 Nm
  • Cross-Section of Flexible Cable (cord) at Terminal: 16 mm²
  • Cross-Section of Rigid Conductor (wire) at Terminal: 25 mm²
  • Type of Connection: screw

Equipment

  • Additional Accessories: Yes

Standard

  • Standard: EN 61008-1
  • European RoHS Directive: compliant
  • European WEEE Directive: Yes

Safety

  • Degree of Protection: IP20
  • Type of Residual Current Switch: A
  • Pollution Degree according to IEC 60664 / IEC 60947-2: 2
  • Storage Temperature: -55 to 70 °C

Device Group Name: CP{Number of Poles} 4 . {Rated current [A]} 40 . {Tenderness} A . {Ingress Protection [IP]} IP20 . {Rated Residual Current [A]} 0.3

Manufacturer

Type
Earth Leakage
Number of Poles
4
Voltage
500 V
Nominal Voltage
40 A
Leakage Current
300 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A