Phase Relays

Hager Phase Relay Earth Leakage 16A Four-Poles with Voltage 230V

Residual current circuit breaker 3+N B 16A 0.03A Type A 6kA RCBO (ADZ316D)

  • Rated current: 16 A
  • Circuit breaker type: B
  • Rated short-circuit breaking capacity Icn: 6 kA
  • Rated residual current dI: 30 mA...

Residual current circuit breaker 3+N B 16A 0.03A Type A 6kA RCBO (ADZ316D)

  • Rated current: 16 A
  • Circuit breaker type: B
  • Rated short-circuit breaking capacity Icn: 6 kA
  • Rated residual current dI: 30 mA
  • Number of poles: 4 P
  • Rated operational voltage Ue (AC): 230 V
  • Rated insulation voltage Ui: 500 V
  • Rated frequency: 50 Hz
  • Tightening torque: 2 Nm
  • Operating...
See full description See full description

Learn more about invoicing

Description

Description

Residual current circuit breaker 3+N B 16A 0.03A Type A 6kA RCBO (ADZ316D)

  • Rated current: 16 A
  • Circuit breaker type: B
  • Rated short-circuit breaking capacity Icn: 6 kA
  • Rated residual current dI: 30 mA
  • Number of poles: 4 P
  • Rated operational voltage Ue (AC): 230 V
  • Rated insulation voltage Ui: 500 V
  • Rated frequency: 50 Hz
  • Tightening torque: 2 Nm
  • Operating temperature: -5 to 40 °C
  • Storage temperature: -55 to 70 °C
  • Product dimensions: Height 86 mm, Width 71 mm, Depth 70 mm
  • Number of electrical endurance cycles: 2000
  • Number of mechanical endurance cycles: 2000
  • Quick connection: yes
  • Terminal capacity for flexible cable: 1/10 mm²
  • Minimum cross-section of screw terminals (wires): 1/16 mm²
  • Maximum cross-section of screw terminals (wires): 1/4 mm²
  • Terminal capacity for flexible cable: 1/4 mm²

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Number of Poles
4
Voltage
230 V
Nominal Voltage
16 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Residual current circuit breaker 3+N B 16A 0.03A Type A 6kA RCBO (ADZ316D)

  • Rated current: 16 A
  • Circuit breaker type: B
  • Rated short-circuit breaking capacity Icn: 6 kA
  • Rated residual current dI: 30 mA
  • Number of poles: 4 P
  • Rated operational voltage Ue (AC): 230 V
  • Rated insulation voltage Ui: 500 V
  • Rated frequency: 50 Hz
  • Tightening torque: 2 Nm
  • Operating temperature: -5 to 40 °C
  • Storage temperature: -55 to 70 °C
  • Product dimensions: Height 86 mm, Width 71 mm, Depth 70 mm
  • Number of electrical endurance cycles: 2000
  • Number of mechanical endurance cycles: 2000
  • Quick connection: yes
  • Terminal capacity for flexible cable: 1/10 mm²
  • Minimum cross-section of screw terminals (wires): 1/16 mm²
  • Maximum cross-section of screw terminals (wires): 1/4 mm²
  • Terminal capacity for flexible cable: 1/4 mm²

Manufacturer

Type
Earth Leakage
Number of Poles
4
Voltage
230 V
Nominal Voltage
16 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

191,90 €
14,00 €   shipping cost