Automatic Circuit Breaker

Eaton Automatic Circuit Breaker 125A AC 111896

Power Switch LZMC1-A125-I - 111896

Protection against overload and short circuit in three-phase circuits 40–1600A.

  • Adjustable tripping for overload and short circuit activation.
  • No reduced nominal...

Power Switch LZMC1-A125-I - 111896

Protection against overload and short circuit in three-phase circuits 40–1600A.

  • Adjustable tripping for overload and short circuit activation.
  • No reduced nominal power values for temperatures up to +50°C.
  • Vertical assembly, 90° position in all directions.
  • Manufactured according to EN 60947-2.
  • Switches and breakers of the...
See full description See full description

Learn more about invoicing

Description

Description

Power Switch LZMC1-A125-I - 111896

Protection against overload and short circuit in three-phase circuits 40–1600A.

  • Adjustable tripping for overload and short circuit activation.
  • No reduced nominal power values for temperatures up to +50°C.
  • Vertical assembly, 90° position in all directions.
  • Manufactured according to EN 60947-2.
  • Switches and breakers of the same design and dimensions.
  • Voltage activation capability.
  • Auxiliary contacts for switch/disconnection status indication.
  • Mechanisms: Rotary mounted directly on the switch; Rotary door; Remote.

Technical Specifications:

  • Rated current: 125A.
  • Number of contacts: 3.
  • Maximum rated voltage: 690 V AC.
  • Impulse withstand voltage UImp: 6 kV.
  • Set range - overload activation: 100-125A.
  • Set range - fast short circuit activation: 750-1250A.
  • Short circuit capacity: 36kA.
  • Mechanical endurance: 20000 cycles.
  • Connection endurance: 8000 cycles.
  • Maximum number of auxiliary contacts for switch construction: 1 unit.
  • Maximum number of release indications: 1 unit.

Manufacturer

See full description

Specifications

Specifications

Specifications

Rated Current
125 A

Power Supply

AC
Yes
DC
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Power Switch LZMC1-A125-I - 111896

Protection against overload and short circuit in three-phase circuits 40–1600A.

  • Adjustable tripping for overload and short circuit activation.
  • No reduced nominal power values for temperatures up to +50°C.
  • Vertical assembly, 90° position in all directions.
  • Manufactured according to EN 60947-2.
  • Switches and breakers of the same design and dimensions.
  • Voltage activation capability.
  • Auxiliary contacts for switch/disconnection status indication.
  • Mechanisms: Rotary mounted directly on the switch; Rotary door; Remote.

Technical Specifications:

  • Rated current: 125A.
  • Number of contacts: 3.
  • Maximum rated voltage: 690 V AC.
  • Impulse withstand voltage UImp: 6 kV.
  • Set range - overload activation: 100-125A.
  • Set range - fast short circuit activation: 750-1250A.
  • Short circuit capacity: 36kA.
  • Mechanical endurance: 20000 cycles.
  • Connection endurance: 8000 cycles.
  • Maximum number of auxiliary contacts for switch construction: 1 unit.
  • Maximum number of release indications: 1 unit.

Manufacturer

Specifications

Rated Current
125 A

Power Supply

AC
Yes
DC
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

461,90 €
14,00 €   shipping cost