Phase Relays

Legrand Phase Relay Earth Leakage 32A Four-Poles with Voltage 230V

Legrand P314 411242 residual current switch 4P C32A 0.3A type A DX3

  • Nominal short-circuit current 6000 A according to IEC 61009-1
  • Type 230 V ~ AC - detects sinusoidal alternating currents Type A
  • ...

Legrand P314 411242 residual current switch 4P C32A 0.3A type A DX3

  • Nominal short-circuit current 6000 A according to IEC 61009-1
  • Type 230 V ~ AC - detects sinusoidal alternating currents Type A
  • Detects sinusoidal alternating and pulsating direct currents
  • Four-pole 400 V~
  • Type A
  • Characteristic C
  • Nominal residual current: 300 mA
  • Nominal current: 32 A
  • Width...
See full description See full description

Description

Description

Legrand P314 411242 residual current switch 4P C32A 0.3A type A DX3

  • Nominal short-circuit current 6000 A according to IEC 61009-1
  • Type 230 V ~ AC - detects sinusoidal alternating currents Type A
  • Detects sinusoidal alternating and pulsating direct currents
  • Four-pole 400 V~
  • Type A
  • Characteristic C
  • Nominal residual current: 300 mA
  • Nominal current: 32 A
  • Width in units 17.5 mm
  • Mounting on TH35 rail
  • Can be connected with a comb or pin rails
  • Can be equipped with auxiliary contacts, triggers, and motors from the DX³ series
  • Gray switching lever

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Number of Poles
4
Voltage
230 V
Nominal Voltage
32 A
Leakage Current
300 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Legrand P314 411242 residual current switch 4P C32A 0.3A type A DX3

  • Nominal short-circuit current 6000 A according to IEC 61009-1
  • Type 230 V ~ AC - detects sinusoidal alternating currents Type A
  • Detects sinusoidal alternating and pulsating direct currents
  • Four-pole 400 V~
  • Type A
  • Characteristic C
  • Nominal residual current: 300 mA
  • Nominal current: 32 A
  • Width in units 17.5 mm
  • Mounting on TH35 rail
  • Can be connected with a comb or pin rails
  • Can be equipped with auxiliary contacts, triggers, and motors from the DX³ series
  • Gray switching lever

Manufacturer

Type
Earth Leakage
Number of Poles
4
Voltage
230 V
Nominal Voltage
32 A
Leakage Current
300 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

238,77 €