Phase Relays

Hager Phase Relay Earth Leakage 10A Bipolar with Voltage 230V

Residual current circuit breaker 1+N 10A B 0.03A AC ADA910D

  • Rated current: 10A
  • Tripping characteristics: B
  • Rated short-circuit breaking capacity: 6kA
  • Type of residual current device: AC
  • Rated...

Residual current circuit breaker 1+N 10A B 0.03A AC ADA910D

  • Rated current: 10A
  • Tripping characteristics: B
  • Rated short-circuit breaking capacity: 6kA
  • Type of residual current device: AC
  • Rated differential current: 30mA
  • Number of poles: 2P
  • Number of modules: 2
  • Rated operational voltage Ue (AC): 240
  • Rated insulation voltage Ui: 2000
  • Rated impulse withstand...
See full description See full description

Learn more about invoicing

Description

Description

Residual current circuit breaker 1+N 10A B 0.03A AC ADA910D

  • Rated current: 10A
  • Tripping characteristics: B
  • Rated short-circuit breaking capacity: 6kA
  • Type of residual current device: AC
  • Rated differential current: 30mA
  • Number of poles: 2P
  • Number of modules: 2
  • Rated operational voltage Ue (AC): 240
  • Rated insulation voltage Ui: 2000
  • Rated impulse withstand voltage Uimp: 6000
  • Frequency: 50Hz
  • Total power loss at rated current: 3.4 W
  • Electrical endurance (number of cycles): 2000
  • Mechanical endurance (number of cycles): 2000
  • Operating temperature: -25 to 40 °C
  • Storage temperature: -25 to 70 °C
  • Height of installed product: 83mm
  • Width of installed product: 35mm
  • Depth of installed product: 68mm
  • Ingress Protection [IP]: IP2X

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Number of Poles
2
Voltage
230 V
Nominal Voltage
10 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type AC

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Residual current circuit breaker 1+N 10A B 0.03A AC ADA910D

  • Rated current: 10A
  • Tripping characteristics: B
  • Rated short-circuit breaking capacity: 6kA
  • Type of residual current device: AC
  • Rated differential current: 30mA
  • Number of poles: 2P
  • Number of modules: 2
  • Rated operational voltage Ue (AC): 240
  • Rated insulation voltage Ui: 2000
  • Rated impulse withstand voltage Uimp: 6000
  • Frequency: 50Hz
  • Total power loss at rated current: 3.4 W
  • Electrical endurance (number of cycles): 2000
  • Mechanical endurance (number of cycles): 2000
  • Operating temperature: -25 to 40 °C
  • Storage temperature: -25 to 70 °C
  • Height of installed product: 83mm
  • Width of installed product: 35mm
  • Depth of installed product: 68mm
  • Ingress Protection [IP]: IP2X

Manufacturer

Type
Earth Leakage
Number of Poles
2
Voltage
230 V
Nominal Voltage
10 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type AC

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

104,90 €
14,00 €   shipping cost