F&F Electric Panel Meter Digital Three-phase LE-03MB-CT

The LE-03MB-CT meter is a static, calibrated, single-phase or three-phase alternating electricity meter, semi-remote connection, bidirectional, and with 4 quarters. It is designed for indicating and...

The LE-03MB-CT meter is a static, calibrated, single-phase or three-phase alternating electricity meter, semi-remote connection, bidirectional, and with 4 quarters. It is designed for indicating and recording energy and network parameters, with remote reading via a wired M-Bus network. It works with current transformers (CT) with secondary current of 1A or...

See full description See full description

Top specs

  • See all

Learn more about invoicing

Description

Description

The LE-03MB-CT meter is a static, calibrated, single-phase or three-phase alternating electricity meter, semi-remote connection, bidirectional, and with 4 quarters. It is designed for indicating and recording energy and network parameters, with remote reading via a wired M-Bus network. It works with current transformers (CT) with secondary current of 1A or 5A. Configuration is done via the front panel menu or through the M-Bus port.

  • Functions and measured values:
  • 3-phase, bidirectional (4 quarters)
  • Transformers 1A or 5A
  • Current ratio adjustment 1÷9999 and voltage ratio adjustment 1÷9999
  • Adjustable measurement voltage 100÷500V
  • kWh/kvar display (consumed/returned)
  • Network parameters display
  • Compliance with LVD
  • M-Bus port/protocol
  • Pulse output SO
  • Backlit multifunctional LCD display
  • Configuration protection with password
  • Active energy AE+/AE- [kWh], reactive energy RE+/RE- [kvarh]
  • Phase voltages U1, U2, U3 [V] and phase currents I1, I2, I3 [A]
  • Frequency F [Hz], active power P [W], reactive power Q [var], apparent power S [VA]
  • Power factor cosϕ, harmonic THD, power and current demand
  • Technical specifications:
  • Reference voltage: 3×230/400V+N
  • Basic current*: 0.25÷5A
  • Maximum current*: 6A
  • Minimum measurable current*: 0.02A
  • Measured voltage: L-N 100÷289V AC, L-L 173÷500V AC
  • Measurement accuracy (according to IEC61036): class 1
  • Overload withstand: 30×lmax/10ms
  • Insulation: 4kV/1min, 6kV/1μs
  • Meter display range: 0÷9999999.99kWh
  • kWh meter constant: 0.01, 0.1, 10, 100 imp/kWh
  • kvarh meter constant: 0.01, 0.1, 10, 100 imp/kvar
  • Reading indicator: 2×LED
  • kWh/kvarh pulse output: open collector
  • Pulse duration for kWh/kvarh: 60, 100, 200 ms
  • Operating temperature: -20÷55°C
  • Connection: screw terminals 25mm²
  • Dimensions: 4.5 units (76mm)
  • Installation: on TH-35 mm rail
  • Protection degree: IP51

Manufacturer

See full description

Specifications

Specifications

Display Type
Digital
Number of Phases
Three-phase
Maximum Current
5 A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The LE-03MB-CT meter is a static, calibrated, single-phase or three-phase alternating electricity meter, semi-remote connection, bidirectional, and with 4 quarters. It is designed for indicating and recording energy and network parameters, with remote reading via a wired M-Bus network. It works with current transformers (CT) with secondary current of 1A or 5A. Configuration is done via the front panel menu or through the M-Bus port.

  • Functions and measured values:
  • 3-phase, bidirectional (4 quarters)
  • Transformers 1A or 5A
  • Current ratio adjustment 1÷9999 and voltage ratio adjustment 1÷9999
  • Adjustable measurement voltage 100÷500V
  • kWh/kvar display (consumed/returned)
  • Network parameters display
  • Compliance with LVD
  • M-Bus port/protocol
  • Pulse output SO
  • Backlit multifunctional LCD display
  • Configuration protection with password
  • Active energy AE+/AE- [kWh], reactive energy RE+/RE- [kvarh]
  • Phase voltages U1, U2, U3 [V] and phase currents I1, I2, I3 [A]
  • Frequency F [Hz], active power P [W], reactive power Q [var], apparent power S [VA]
  • Power factor cosϕ, harmonic THD, power and current demand
  • Technical specifications:
  • Reference voltage: 3×230/400V+N
  • Basic current*: 0.25÷5A
  • Maximum current*: 6A
  • Minimum measurable current*: 0.02A
  • Measured voltage: L-N 100÷289V AC, L-L 173÷500V AC
  • Measurement accuracy (according to IEC61036): class 1
  • Overload withstand: 30×lmax/10ms
  • Insulation: 4kV/1min, 6kV/1μs
  • Meter display range: 0÷9999999.99kWh
  • kWh meter constant: 0.01, 0.1, 10, 100 imp/kWh
  • kvarh meter constant: 0.01, 0.1, 10, 100 imp/kvar
  • Reading indicator: 2×LED
  • kWh/kvarh pulse output: open collector
  • Pulse duration for kWh/kvarh: 60, 100, 200 ms
  • Operating temperature: -20÷55°C
  • Connection: screw terminals 25mm²
  • Dimensions: 4.5 units (76mm)
  • Installation: on TH-35 mm rail
  • Protection degree: IP51

Manufacturer

Display Type
Digital
Number of Phases
Three-phase
Maximum Current
5 A