The Carlo Gavazzi E83-2050 transducer measures an input current from 0 to 50 A and provides a 4–20 mA analog output. It is mounted on a DIN rail and powered by 10–40 V DC.

  • Current rating: 50 A
  • Input...

The Carlo Gavazzi E83-2050 transducer measures an input current from 0 to 50 A and provides a 4–20 mA analog output. It is mounted on a DIN rail and powered by 10–40 V DC.

  • Current rating: 50 A
  • Input current range: 0–50 A
  • Maximum continuous current: 100 A
  • Maximum overload current for 10 s: 300 A
  • Output current: 4–20 mA
  • Maximum output current: 30 mA
  • Supply...
See full description See full description
359 91 €
Delivery Thu, 03 Dec - Wed, 09 Dec
14,00 €   shipping cost
Sent from Greece
From Getters 4.6 (118)

Learn more about invoicing

Description

Description

The Carlo Gavazzi E83-2050 transducer measures an input current from 0 to 50 A and provides a 4–20 mA analog output. It is mounted on a DIN rail and powered by 10–40 V DC.

  • Current rating: 50 A
  • Input current range: 0–50 A
  • Maximum continuous current: 100 A
  • Maximum overload current for 10 s: 300 A
  • Output current: 4–20 mA
  • Maximum output current: 30 mA
  • Supply voltage: 10–40 V DC
  • Overvoltage category: III
  • Degree of protection: IP20
  • Pollution degree: 3
  • Temperature range: -20 to 50 °C
  • Dimensions: 22.5 x 56 x 49 mm

Manufacturer

See full description

Specifications

Specifications

Voltage
-
Current
50 A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The Carlo Gavazzi E83-2050 transducer measures an input current from 0 to 50 A and provides a 4–20 mA analog output. It is mounted on a DIN rail and powered by 10–40 V DC.

  • Current rating: 50 A
  • Input current range: 0–50 A
  • Maximum continuous current: 100 A
  • Maximum overload current for 10 s: 300 A
  • Output current: 4–20 mA
  • Maximum output current: 30 mA
  • Supply voltage: 10–40 V DC
  • Overvoltage category: III
  • Degree of protection: IP20
  • Pollution degree: 3
  • Temperature range: -20 to 50 °C
  • Dimensions: 22.5 x 56 x 49 mm