The Uni-T UT336A leak detector detects CFC, HCFC, and HFC refrigerants using a negative corona sensor, with a maximum sensitivity of 3 g/a. It is used for servicing air conditioners, cars, and refrigerators. It features six adjustable sensitivity levels, automatic zero adjustment on startup, and visual and audible alerts.
Warm-up takes 3 seconds. The device features a battery status indicator, mute function, and automatic power-off. The sensor has an approximate lifespan of 50 hours under normal detection conditions.
- Sensor type: Negative corona
- Detectable refrigerants: CFC, HCFC, HFC
- Maximum sensitivity: 3 g/a
- Sensitivity levels: 6
- Visual alert levels: 6
- Warm-up time: 3 s
- Battery status indicator: Yes
- Automatic zero adjustment: Yes
- Mute function: Yes
- Automatic power-off: Yes
- Sensor lifespan: Approximately 50 h under normal detection conditions
- Operating time: 20 h
- Operating temperature: 0 °C–50 °C
- Operating humidity: Below 95% RH, non-condensing
- Power supply: 4 AA batteries
- Dimensions: 190 × 65 × 43 mm, excluding the sensor cable
- Net weight: 312 g, excluding batteries
- Package contents: Refrigerant leak detector, 4 AA batteries, auxiliary sensor, user manual
- Type
- Leakage Meter
- Digital
- No
Important information
Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.