Phase Relays

Legrand 30ma Phase 4-Pole Earth Leakage Relay 400V

The Legrand 411663 four-pole residual current device mounts on a DIN rail and is designed for three-phase installations. It is Type A and has a sensitivity of 30 mA.

  • Type: Type A residual current...

The Legrand 411663 four-pole residual current device mounts on a DIN rail and is designed for three-phase installations. It is Type A and has a sensitivity of 30 mA.

  • Type: Type A residual current device
  • Number of poles: 4
  • Rated current: 80 A
  • Residual current: 30 mA
  • Rated voltage: 400 V
  • Rated operating voltage: 320–440 V
  • Rated insulation voltage: 500 V
  • Rated...
See Description & Specifications See Description & Specifications
92 78 €
Delivery by Thu, 19 Nov
14,00 €   shipping cost
Sent from Greece
From E-damianakis 4.9 (16)

Learn more about invoicing

Description & Specifications

The Legrand 411663 four-pole residual current device mounts on a DIN rail and is designed for three-phase installations. It is Type A and has a sensitivity of 30 mA.

  • Type: Type A residual current device
  • Number of poles: 4
  • Rated current: 80 A
  • Residual current: 30 mA
  • Rated voltage: 400 V
  • Rated operating voltage: 320–440 V
  • Rated insulation voltage: 500 V
  • Rated impulse withstand voltage: 4 kV
  • Frequency: 50 Hz
  • Mounting method: DIN rail
  • Connection type: Screw terminal, busbar and cable
  • Flexible connecting cable cross-section: 0.75–35 mm²
  • Rigid connecting cable cross-section: 0.75–50 mm²
  • Supply direction: From above or below
  • Short-circuit withstand capacity: 10 kA
  • Impulse current withstand capacity: 0.25 kA
  • Protection rating: IP20
  • Width in modules: 4
  • Width: 71.2 mm
  • Height: 83 mm
  • Depth: 77.8 mm
  • Installation depth: 44 mm
  • Operating temperature: -25 to 60 °C
  • Storage temperature: -40 to 70 °C
  • Pollution degree: 2
  • Impact resistance: IK04
  • Colour: Grey
  • Locking: With locking mechanism
  • Auxiliary products: Compatible with auxiliary products
  • Terminal marking: With identification marking
  • Label area: With space for a label
  • Halogen-free: Yes

Manufacturer

Type
Earth Leakage
Number of Poles
4
Voltage
400 V
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A