Automatic Circuit Breaker

Dehn Automatic Circuit Breaker 100A Single-pole AC/DC 952087

Surge arrester DEHNguard

  • Type: 2
  • Class: II
  • Maximum continuous operating voltage: 275 V AC / 350 V DC
  • Nominal discharge current: 10 kA
  • Maximum discharge current: 20 kA
  • Voltage protection level: =< 1.5 kV
  • ...
  • < 1.5 kV

Surge arrester DEHNguard

  • Type: 2
  • Class: II
  • Maximum continuous operating voltage: 275 V AC / 350 V DC
  • Nominal discharge current: 10 kA
  • Maximum discharge current: 20 kA
  • Voltage protection level: =< 1.5 kV
  • Response time: =< 100 ns
  • Maximum backup fuse: 100 A gL / gG
  • Short-circuit withstand capability with maximum backup fuse: 25 kA
  • Temporary overvoltage: 335 / 5 seconds
  • ...
  • < 100 ns< 1.5 kV
See full description See full description

Learn more about invoicing

Description

Description

Surge arrester DEHNguard

  • Type: 2
  • Class: II
  • Maximum continuous operating voltage: 275 V AC / 350 V DC
  • Nominal discharge current: 10 kA
  • Maximum discharge current: 20 kA
  • Voltage protection level: =< 1.5 kV
  • Response time: =< 100 ns
  • Maximum backup fuse: 100 A gL / gG
  • Short-circuit withstand capability with maximum backup fuse: 25 kA
  • Temporary overvoltage: 335 / 5 seconds
  • Temporary overvoltage - Characteristic: Resistant
  • Operating temperature range: from -40 to +80 °C
  • Operation / fault indicator: green / red
  • Minimum cable cross-section: 1.5 mm² (solid / stranded)
  • Maximum cable cross-section: 35 mm² (multi-stranded) / 25 mm² (stranded)
  • Mounting: 35 mm rail
  • Housing material: thermoplastic, red
  • Degree of protection: IP20
  • Mounting width: 1 module
  • Fault signaling FM / contact type: switch
  • Signaling circuit parameters AC: 250 V / 0.5 A
  • Signaling circuit parameters DC: 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
  • Signaling FM cable cross-sections: maximum 1.5 mm² (solid / stranded)
  • Insulated: yes
  • Number of poles: 1

Manufacturer

See full description

Specifications

Specifications

Specifications

Number of Poles
1
Rated Current
100 A
Operating Curve
Curve C

Power Supply

AC
Yes
DC
Yes

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Surge arrester DEHNguard

  • Type: 2
  • Class: II
  • Maximum continuous operating voltage: 275 V AC / 350 V DC
  • Nominal discharge current: 10 kA
  • Maximum discharge current: 20 kA
  • Voltage protection level: =< 1.5 kV
  • Response time: =< 100 ns
  • Maximum backup fuse: 100 A gL / gG
  • Short-circuit withstand capability with maximum backup fuse: 25 kA
  • Temporary overvoltage: 335 / 5 seconds
  • Temporary overvoltage - Characteristic: Resistant
  • Operating temperature range: from -40 to +80 °C
  • Operation / fault indicator: green / red
  • Minimum cable cross-section: 1.5 mm² (solid / stranded)
  • Maximum cable cross-section: 35 mm² (multi-stranded) / 25 mm² (stranded)
  • Mounting: 35 mm rail
  • Housing material: thermoplastic, red
  • Degree of protection: IP20
  • Mounting width: 1 module
  • Fault signaling FM / contact type: switch
  • Signaling circuit parameters AC: 250 V / 0.5 A
  • Signaling circuit parameters DC: 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A
  • Signaling FM cable cross-sections: maximum 1.5 mm² (solid / stranded)
  • Insulated: yes
  • Number of poles: 1

Manufacturer

Specifications

Number of Poles
1
Rated Current
100 A
Operating Curve
Curve C

Power Supply

AC
Yes
DC
Yes

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.