Siemens Phase 2-Pole Earth Leakage Relay 10A 230V

The Siemens 5SV1316-6KK10 residual current circuit breaker combines Type A residual current protection with a rated current of 10 A. Its 30 mA tripping sensitivity and 230 V operating voltage make it...

The Siemens 5SV1316-6KK10 residual current circuit breaker combines Type A residual current protection with a rated current of 10 A. Its 30 mA tripping sensitivity and 230 V operating voltage make it suitable for protection against electric shock and the effects of short circuits.

  • Type: Residual current circuit breaker
  • Number of poles: 2
  • Rated current: 10 A...
See Description & Specifications See Description & Specifications
165 90 €
Delivery Tue, 24 Nov - Mon, 30 Nov
14,00 €   shipping cost
Sent from Greece
From Getters 4.5 (117)

Learn more about invoicing

Description & Specifications

The Siemens 5SV1316-6KK10 residual current circuit breaker combines Type A residual current protection with a rated current of 10 A. Its 30 mA tripping sensitivity and 230 V operating voltage make it suitable for protection against electric shock and the effects of short circuits.

  • Type: Residual current circuit breaker
  • Number of poles: 2
  • Rated current: 10 A
  • Operating voltage: 230 V
  • Residual current protection type: Type A
  • Residual tripping current: 30 mA
  • Degree of protection: IP20
  • Mechanical service life: 10,000 switching cycles
  • Overvoltage category: III
  • Pollution degree: 2
  • Impulse current withstand: 1 kA
  • Supply frequency: 50 Hz
  • Switching capacity (EN 60898): 6 kA
  • Switching capacity (IEC 60947-2): 25 kA
  • Energy-limiting class: 3
  • Power loss in the hot state: 1.1 W
  • Maximum power loss: 2.2 W
  • Operating current at 40 °C: 9.4 A
  • Operating current at 70 °C: 7.4 A
  • Dimensions: 90 × 18 × 77 mm (height × width × depth)
  • Net weight: 117 g
  • Operating temperature: -25 °C to 45 °C
  • Storage temperature: -40 °C to 75 °C
  • Test cycles (IEC 60068-2-30): 28
  • Connectable conductors: Solid and stranded conductors, 0.75 mm² to 16 mm²; flexible conductors with ferrules up to 10 mm²
  • Standards: EN 60898 and IEC 60947-2
  • Series: SENTRON 5SV1

Manufacturer

Type
Earth Leakage
Number of Poles
2
Voltage
230 V
Nominal Voltage
10 A
Leakage Current
30 mA
with Energy Consumption Meter
No
with Timer
No
Type of Residual Current Relay
Type A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

165,90 €
14,00 €   shipping cost