Electric Panel Meters

Sinotimer Digital Electric Panel Meter Rail Three-phase

Technical Documentation of Sinotimer DDS576 Three-Phase Electric Energy Meter

  • Product Name: Three-Phase Electric Energy Meter
  • Model: Sinotimer DDS576
  • Type: Three-phase electronic meter for measuring...

Technical Documentation of Sinotimer DDS576 Three-Phase Electric Energy Meter

  • Product Name: Three-Phase Electric Energy Meter
  • Model: Sinotimer DDS576
  • Type: Three-phase electronic meter for measuring electric energy (kWh)

Technical Data

  • Rated Voltage: 3 x 230/400 V AC, 50 Hz
  • Rated Current: 3 x 5 A
  • Maximum Current: 100 A
  • Pulse Constant: 400 imp/kWh
  • Pulse...
See full description See full description
  • See all
The product is not available for shipping to the selected country.

Description

Description

Technical Documentation of Sinotimer DDS576 Three-Phase Electric Energy Meter

  • Product Name: Three-Phase Electric Energy Meter
  • Model: Sinotimer DDS576
  • Type: Three-phase electronic meter for measuring electric energy (kWh)

Technical Data

  • Rated Voltage: 3 x 230/400 V AC, 50 Hz
  • Rated Current: 3 x 5 A
  • Maximum Current: 100 A
  • Pulse Constant: 400 imp/kWh
  • Pulse Output: Yes, with optical isolation
  • LED Indicator: Yes, pulse indication
  • Installation: DIN 35 mm
  • Dimensions (L x W x H): 125 x 73 x 88 mm
  • Weight: 560 g
  • Display: Digital LED (kWh)

Main Features

  • Measurement of electric energy (kWh)
  • Consumption indication on LED display
  • Pulse output for connection with external monitoring systems (400 imp/kWh)
  • LED indicator for meter operation
  • Quick installation on DIN rail, ideal for electric panels

Application Areas

  • Energy consumption monitoring in industrial and commercial three-phase installations
  • Electric distribution panels
  • Energy management systems
  • Integration with monitoring systems via pulse output

Installation and Mounting

  • Installation: on 35 mm DIN rail
  • Connection: Phases and neutral to specified terminals
  • Polarity and phase sequence compliance
  • Recommended protection: fuses or circuit breakers for each phase
  • Precautions: Installation must be performed only by qualified personnel. Work only with power off.

Operation and Indications

  • LED Display: shows total consumption in kWh
  • Pulse LED: pulses proportional to consumed energy (400 imp/kWh)
  • Memory: accumulated consumption remains stored even after power outage

Environmental Specifications

  • Operating Temperature: -20°C to +55°C (typical for these types of meters)
  • Maximum Humidity: 75% RH
  • Accuracy Class: 1.0

Notes and Recommendations

  • For proper use, periodic verification of electrical connections is necessary.
  • Do not use in environments with excessive dust, high humidity, or extreme temperatures.
  • Recommended for electric panels with sufficient space and appropriate ventilation.

Manufacturer

See full description

Specifications

Specifications

Display Type
Digital
Installation Type
Rail
Number of Phases
Three-phase
Maximum Current
100 A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Technical Documentation of Sinotimer DDS576 Three-Phase Electric Energy Meter

  • Product Name: Three-Phase Electric Energy Meter
  • Model: Sinotimer DDS576
  • Type: Three-phase electronic meter for measuring electric energy (kWh)

Technical Data

  • Rated Voltage: 3 x 230/400 V AC, 50 Hz
  • Rated Current: 3 x 5 A
  • Maximum Current: 100 A
  • Pulse Constant: 400 imp/kWh
  • Pulse Output: Yes, with optical isolation
  • LED Indicator: Yes, pulse indication
  • Installation: DIN 35 mm
  • Dimensions (L x W x H): 125 x 73 x 88 mm
  • Weight: 560 g
  • Display: Digital LED (kWh)

Main Features

  • Measurement of electric energy (kWh)
  • Consumption indication on LED display
  • Pulse output for connection with external monitoring systems (400 imp/kWh)
  • LED indicator for meter operation
  • Quick installation on DIN rail, ideal for electric panels

Application Areas

  • Energy consumption monitoring in industrial and commercial three-phase installations
  • Electric distribution panels
  • Energy management systems
  • Integration with monitoring systems via pulse output

Installation and Mounting

  • Installation: on 35 mm DIN rail
  • Connection: Phases and neutral to specified terminals
  • Polarity and phase sequence compliance
  • Recommended protection: fuses or circuit breakers for each phase
  • Precautions: Installation must be performed only by qualified personnel. Work only with power off.

Operation and Indications

  • LED Display: shows total consumption in kWh
  • Pulse LED: pulses proportional to consumed energy (400 imp/kWh)
  • Memory: accumulated consumption remains stored even after power outage

Environmental Specifications

  • Operating Temperature: -20°C to +55°C (typical for these types of meters)
  • Maximum Humidity: 75% RH
  • Accuracy Class: 1.0

Notes and Recommendations

  • For proper use, periodic verification of electrical connections is necessary.
  • Do not use in environments with excessive dust, high humidity, or extreme temperatures.
  • Recommended for electric panels with sufficient space and appropriate ventilation.

Manufacturer

Display Type
Digital
Installation Type
Rail
Number of Phases
Three-phase
Maximum Current
100 A