Electric Panel Meters

Eastron Modbus Electric Panel Meter Analog Rail Three-phase Modbus SDM630-M

The Eastron SDM630 M Modbus energy meter is a three-phase meter equipped with an RS-485 port and a certified MID Modbus-RTU protocol. It includes two pulse outputs, one of which is adjustable. The...

The Eastron SDM630 M Modbus energy meter is a three-phase meter equipped with an RS-485 port and a certified MID Modbus-RTU protocol. It includes two pulse outputs, one of which is adjustable. The meter measures and displays supply characteristics of single-phase with two wires (1p2w), three-phase with three wires (3p3w), and three-phase with four wires...

See full description See full description

Description

Description

The Eastron SDM630 M Modbus energy meter is a three-phase meter equipped with an RS-485 port and a certified MID Modbus-RTU protocol. It includes two pulse outputs, one of which is adjustable. The meter measures and displays supply characteristics of single-phase with two wires (1p2w), three-phase with three wires (3p3w), and three-phase with four wires (3p4w).

The measured parameters include:

  • Voltage (V)
  • Frequency (Hz)
  • Current (A)
  • Capacity (kW/kVA/kVAR)
  • Consumed energy (import)
  • Supplied energy (export)
  • Total energy (kWh/kVARh)

Additionally, it indicates peak current flow and power demand, measured at adjustable intervals from 1 to 60 minutes. The meter operates with a load up to 100A and does not require connection to current transformers (CT).

Technical specifications:

  • AC Voltage (Un): 3x230(400)V
  • Voltage range: 80 ~ 120% Un
  • Base current (Ib): 10A
  • Maximum current (Imax): 100A
  • Minimum current (Imin): 0.3A
  • Starting current: 0.4% Ib
  • Power consumption: 2W/10VA (voltage measurement circuit), 4VA (current measurement circuit)
  • Voltage accuracy: 0.5% of full scale
  • Current accuracy: 0.5% of nominal current
  • Frequency accuracy: 0.2% of average frequency
  • Power factor accuracy: 1% of the unit (0.01)
  • Active power accuracy (W): 1% of full scale
  • Reactive power accuracy (VAR): 1% of full scale
  • Apparent power accuracy (VA): 1% of full scale
  • Active energy (Wh): Class 1 IEC 62053-21
  • Reactive energy (VARh): 1% of full scale
  • Signal response time: 1 second input step, typically above 99% of final reading at 50 Hz
  • Operating temperature: -40°C to 70°C
  • Storage temperature: -40°C to 70°C
  • Relative humidity: 0 to 95% non-condensing
  • Altitude: up to 2000 m above sea level
  • Warm-up time: 5 seconds
  • Vibration: 10Hz to 50Hz, 2g, IEC 60068-2-6
  • Shock: 30g
  • Protection class: IP51 (indoor)
  • Material: Self-extinguishing UL94 V-0
  • Display: 400 Imp/kWh
  • Dimensions (DIN): 72 x 100 mm (width x height) according to DIN 43880
  • Mounting rail: DIN (DIN 43880)

Manufacturer

See full description

Specifications

Specifications

Specifications

Display Type
Analog
Installation Type
Rail
Number of Phases
Three-phase

Smart Features

Connectivity
Modbus

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The Eastron SDM630 M Modbus energy meter is a three-phase meter equipped with an RS-485 port and a certified MID Modbus-RTU protocol. It includes two pulse outputs, one of which is adjustable. The meter measures and displays supply characteristics of single-phase with two wires (1p2w), three-phase with three wires (3p3w), and three-phase with four wires (3p4w).

The measured parameters include:

  • Voltage (V)
  • Frequency (Hz)
  • Current (A)
  • Capacity (kW/kVA/kVAR)
  • Consumed energy (import)
  • Supplied energy (export)
  • Total energy (kWh/kVARh)

Additionally, it indicates peak current flow and power demand, measured at adjustable intervals from 1 to 60 minutes. The meter operates with a load up to 100A and does not require connection to current transformers (CT).

Technical specifications:

  • AC Voltage (Un): 3x230(400)V
  • Voltage range: 80 ~ 120% Un
  • Base current (Ib): 10A
  • Maximum current (Imax): 100A
  • Minimum current (Imin): 0.3A
  • Starting current: 0.4% Ib
  • Power consumption: 2W/10VA (voltage measurement circuit), 4VA (current measurement circuit)
  • Voltage accuracy: 0.5% of full scale
  • Current accuracy: 0.5% of nominal current
  • Frequency accuracy: 0.2% of average frequency
  • Power factor accuracy: 1% of the unit (0.01)
  • Active power accuracy (W): 1% of full scale
  • Reactive power accuracy (VAR): 1% of full scale
  • Apparent power accuracy (VA): 1% of full scale
  • Active energy (Wh): Class 1 IEC 62053-21
  • Reactive energy (VARh): 1% of full scale
  • Signal response time: 1 second input step, typically above 99% of final reading at 50 Hz
  • Operating temperature: -40°C to 70°C
  • Storage temperature: -40°C to 70°C
  • Relative humidity: 0 to 95% non-condensing
  • Altitude: up to 2000 m above sea level
  • Warm-up time: 5 seconds
  • Vibration: 10Hz to 50Hz, 2g, IEC 60068-2-6
  • Shock: 30g
  • Protection class: IP51 (indoor)
  • Material: Self-extinguishing UL94 V-0
  • Display: 400 Imp/kWh
  • Dimensions (DIN): 72 x 100 mm (width x height) according to DIN 43880
  • Mounting rail: DIN (DIN 43880)

Manufacturer

Specifications

Display Type
Analog
Installation Type
Rail
Number of Phases
Three-phase

Smart Features

Connectivity
Modbus

Important information