The automation control panel is suitable for controlling two traffic lights with two light fields (red & green) or with three light fields (red, yellow & green). It provides a solution for traffic when two opposite directions alternatively use a common lane.
Technical specifications:
- Power supply from network: 230VAC, 50 Hz
- Power supply to accessories: 24VAC (0.4 A max)
- Fuses: 2
- Network power supply fuse: 500mA, fast-blow
- Power supply fuse to traffic lights: 2A, fast-blow
- Outputs: Via relays suitable for a maximum current of 5A at 230VAC
- Sensor inputs: 3 inputs of Normally Open (NO) or Normally Closed (NC) switch type
- Programming method: With 3 keys (+, - and E) and a 4-character 7-segment display
- Indicator LEDs: 2 in total, show the real-time color of the corresponding traffic light
Typical use cases: The panel controls the operation of traffic lights that coordinate traffic flows at points with opposite directions.
Wiring: Installation of sensors is required for logical operation with signals. Inductive loop controllers are preferred due to maximum functionality.
The panel wiring is described in detail in the following diagrams:
- Wiring with 2-field traffic lights (red & green)
- Wiring with 3-field traffic lights (red, orange & green)
- Wi-Fi