Phase Relays

Hager 30ma Ac Phase Earth Leakage Relay 16A 230V

The product belongs to the RCCB (Residual Current Circuit Breaker) category with the following characteristic specifications:

  • Pole Type: 1P+N
  • Curve: C
  • Rated Current: 16 A
  • Rated Residual Operating...

The product belongs to the RCCB (Residual Current Circuit Breaker) category with the following characteristic specifications:

  • Pole Type: 1P+N
  • Curve: C
  • Rated Current: 16 A
  • Rated Residual Operating Current Idn: 30 mA
  • Rated Current at -25°C: 18.50 A
  • Rated Current at -20°C: 18.30 A
  • Rated Current at -15°C: 18.10 A
  • Rated Current at -10°C: 17.90 A
  • Rated Current at...
See full description See full description
This product is temporarily unavailable at Skroutz Last updated: 5 days ago

Description

Description

The product belongs to the RCCB (Residual Current Circuit Breaker) category with the following characteristic specifications:

  • Pole Type: 1P+N
  • Curve: C
  • Rated Current: 16 A
  • Rated Residual Operating Current Idn: 30 mA
  • Rated Current at -25°C: 18.50 A
  • Rated Current at -20°C: 18.30 A
  • Rated Current at -15°C: 18.10 A
  • Rated Current at -10°C: 17.90 A
  • Rated Current at -5°C: 17.70 A
  • Rated Current at 0°C: 17.40 A
  • Rated Current at 5°C: 17.20 A
  • Rated Current at 10°C: 17 A
  • Rated Current at 15°C: 16.70 A
  • Rated Current at 20°C: 16.50 A
  • Rated Current at 25°C: 16.20 A
  • Rated Current at 30°C: 16 A
  • Rated Current at 35°C: 15.80 A
  • Rated Current at 40°C: 15.60 A
  • Rated Current at 50°C: 15.20 A
  • Rated Current at 55°C: 15 A
  • Rated Current at 60°C: 14.80 A
  • Current Correction Factor for 2 devices installed side by side: 1
  • Current Correction Factor for 3 devices installed side by side: 0.95
  • Current Correction Factor for 4 and 5 devices installed side by side: 0.90
  • Current Correction Factor for 6 devices installed side by side: 0.85
  • Minimum/Maximum Thermal Operation Limit Value AC: 1.13 - 1.45 A
  • Rated Short-Circuit Breaking Capacity Icn at 230 V AC according to IEC 60898-1: 6 kA

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Voltage
230 V
Nominal Voltage
16 A
Leakage Current
30 mA

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The product belongs to the RCCB (Residual Current Circuit Breaker) category with the following characteristic specifications:

  • Pole Type: 1P+N
  • Curve: C
  • Rated Current: 16 A
  • Rated Residual Operating Current Idn: 30 mA
  • Rated Current at -25°C: 18.50 A
  • Rated Current at -20°C: 18.30 A
  • Rated Current at -15°C: 18.10 A
  • Rated Current at -10°C: 17.90 A
  • Rated Current at -5°C: 17.70 A
  • Rated Current at 0°C: 17.40 A
  • Rated Current at 5°C: 17.20 A
  • Rated Current at 10°C: 17 A
  • Rated Current at 15°C: 16.70 A
  • Rated Current at 20°C: 16.50 A
  • Rated Current at 25°C: 16.20 A
  • Rated Current at 30°C: 16 A
  • Rated Current at 35°C: 15.80 A
  • Rated Current at 40°C: 15.60 A
  • Rated Current at 50°C: 15.20 A
  • Rated Current at 55°C: 15 A
  • Rated Current at 60°C: 14.80 A
  • Current Correction Factor for 2 devices installed side by side: 1
  • Current Correction Factor for 3 devices installed side by side: 0.95
  • Current Correction Factor for 4 and 5 devices installed side by side: 0.90
  • Current Correction Factor for 6 devices installed side by side: 0.85
  • Minimum/Maximum Thermal Operation Limit Value AC: 1.13 - 1.45 A
  • Rated Short-Circuit Breaking Capacity Icn at 230 V AC according to IEC 60898-1: 6 kA

Manufacturer

Type
Earth Leakage
Voltage
230 V
Nominal Voltage
16 A
Leakage Current
30 mA

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.