Technical Features

  • Architecture: 1P+N
  • Curve: C
  • Protection: Residual current type AC
  • Protection category (IP): IP2X
  • Main electrical characteristics:
    • Rated short-circuit breaking capacity Icn AC...

Technical Features

  • Architecture: 1P+N
  • Curve: C
  • Protection: Residual current type AC
  • Protection category (IP): IP2X
  • Main electrical characteristics:
    • Rated short-circuit breaking capacity Icn AC according to IEC 60898-1: 6 kA
  • Connectivity:
    • Connection type: Terminal codes
  • Voltage:
    • Rated insulation voltage Ui: 500 V
    • Rated impulse withstand voltage Uimp:...
See full description See full description
This product is temporarily unavailable at Skroutz Last updated: 3 days ago

Description

Description

Technical Features

  • Architecture: 1P+N
  • Curve: C
  • Protection: Residual current type AC
  • Protection category (IP): IP2X
  • Main electrical characteristics:
    • Rated short-circuit breaking capacity Icn AC according to IEC 60898-1: 6 kA
  • Connectivity:
    • Connection type: Terminal codes
  • Voltage:
    • Rated insulation voltage Ui: 500 V
    • Rated impulse withstand voltage Uimp: 4,000 V
    • Maximum operating voltage: 240 V
    • Rated operational voltage Ue: 240 - 240 V
    • Overvoltage category according to IEC 60947-1: 3
    • Power supply voltage type: AC
  • Electrical current:
    • Rated current: 20 A
    • Rated residual operating current Idn: 30 mA
    • Rated current -25°C: 22.70 A
    • Rated current -20°C: 22.50 A
    • Rated current -15°C: 22.20 A
    • Rated current -10°C: 22 A
    • Rated current -5°C: 21.80 A
    • Rated current 0°C: 21.50 A
    • Rated current 5°C: 21.30 A
    • Rated current 10°C: 21 A
    • Rated current 15°C: 20.80 A
    • Rated current 20°C: 20.50 A
    • Rated current 25°C: 20.30 A
    • Rated current 30°C: 20 A
    • Rated current 35°C: 19.80 A
    • Rated current 40°C: 19.60 A
    • Rated current 45°C: 19.40 A
    • Rated current 50°C: 19.20 A
    • Rated current 55°C: 19 A
    • Rated current 60°C: 18.80 A
    • Correction factor for current for 2 devices side by side: 1
    • Minimum/maximum threshold value of AC thermal operation: 1.13 - 1.45 A
    • Correction factor for current for 3 devices side by side: 0.95
    • Correction factor for current for 4 and 5 devices side by side: 0.90
    • Correction factor for current for 6 devices side by side: 0.85
    • Rated service breaking capacity Ics AC according to IEC 60898-1: 6 kA

Manufacturer

See full description

Specifications

Specifications

Type
Earth Leakage
Voltage
500 V
Nominal Voltage
20 A
Leakage Current
30 mA
Type of Residual Current Relay
-

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Technical Features

  • Architecture: 1P+N
  • Curve: C
  • Protection: Residual current type AC
  • Protection category (IP): IP2X
  • Main electrical characteristics:
    • Rated short-circuit breaking capacity Icn AC according to IEC 60898-1: 6 kA
  • Connectivity:
    • Connection type: Terminal codes
  • Voltage:
    • Rated insulation voltage Ui: 500 V
    • Rated impulse withstand voltage Uimp: 4,000 V
    • Maximum operating voltage: 240 V
    • Rated operational voltage Ue: 240 - 240 V
    • Overvoltage category according to IEC 60947-1: 3
    • Power supply voltage type: AC
  • Electrical current:
    • Rated current: 20 A
    • Rated residual operating current Idn: 30 mA
    • Rated current -25°C: 22.70 A
    • Rated current -20°C: 22.50 A
    • Rated current -15°C: 22.20 A
    • Rated current -10°C: 22 A
    • Rated current -5°C: 21.80 A
    • Rated current 0°C: 21.50 A
    • Rated current 5°C: 21.30 A
    • Rated current 10°C: 21 A
    • Rated current 15°C: 20.80 A
    • Rated current 20°C: 20.50 A
    • Rated current 25°C: 20.30 A
    • Rated current 30°C: 20 A
    • Rated current 35°C: 19.80 A
    • Rated current 40°C: 19.60 A
    • Rated current 45°C: 19.40 A
    • Rated current 50°C: 19.20 A
    • Rated current 55°C: 19 A
    • Rated current 60°C: 18.80 A
    • Correction factor for current for 2 devices side by side: 1
    • Minimum/maximum threshold value of AC thermal operation: 1.13 - 1.45 A
    • Correction factor for current for 3 devices side by side: 0.95
    • Correction factor for current for 4 and 5 devices side by side: 0.90
    • Correction factor for current for 6 devices side by side: 0.85
    • Rated service breaking capacity Ics AC according to IEC 60898-1: 6 kA

Manufacturer

Type
Earth Leakage
Voltage
500 V
Nominal Voltage
20 A
Leakage Current
30 mA
Type of Residual Current Relay
-

Important information