Electric Panel Meters

Smart Electric Panel Meter Digital Rail Three-phase Modbus HYX-DTSU666-250A

The measuring device competes in its specifications according to the standards EN 61326-1 and EN 61010-1.

  • Measurement type: 3P4W (Three-phase four-wire)
  • Current transformer (CT): Supported
  • Accuracy:...

The measuring device competes in its specifications according to the standards EN 61326-1 and EN 61010-1.

  • Measurement type: 3P4W (Three-phase four-wire)
  • Current transformer (CT): Supported
  • Accuracy: Voltage: 0.5%, Current: 0.5%, Capacity: 1%
  • Nominal voltage (Un): 3x220/380V up to 3240/415V
  • Operating voltage range: 207V ~ 253V
  • Voltage tolerance: 184V ~ 264V
  • ...
See full description See full description
The product is not available for shipping to the selected country.

Description

Description

The measuring device competes in its specifications according to the standards EN 61326-1 and EN 61010-1.

  • Measurement type: 3P4W (Three-phase four-wire)
  • Current transformer (CT): Supported
  • Accuracy: Voltage: 0.5%, Current: ±0.5%, Capacity: ±1%
  • Nominal voltage (Un): 3x220/380V up to 3240/415V
  • Operating voltage range: 207V ~ 253V
  • Voltage tolerance: 184V ~ 264V
  • Nominal current: 250A/50mA
  • Frequency: 50Hz / 60Hz
  • Display: LCD with LED indicators
  • Communication protocol: ModBus-RTU
  • Interface: RS485
  • Communication speeds: 1200/2400/4800/9600 bps (optionally 19200/115200 bps)
  • Measurement parameters: Active/reactive energy (kWh, kvarh), Capacity (kW, kvar, kVA), RMS current (Irms), RMS voltage (Vrms) and others
  • Operating temperature: -25°C to +55°C
  • Storage temperature: -40°C to +70°C
  • Humidity: 95% (non-condensing)
  • Atmospheric pressure: 63.0 kPa to 106.0 kPa
  • Dimensions: 72mm x 100mm x 65.5mm
  • Mounting: DIN rail 35mm

Manufacturer

See full description

Specifications

Specifications

Specifications

Display Type
Digital
Installation Type
Rail
Number of Phases
Three-phase

Smart Features

Connectivity
Modbus

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The measuring device competes in its specifications according to the standards EN 61326-1 and EN 61010-1.

  • Measurement type: 3P4W (Three-phase four-wire)
  • Current transformer (CT): Supported
  • Accuracy: Voltage: 0.5%, Current: ±0.5%, Capacity: ±1%
  • Nominal voltage (Un): 3x220/380V up to 3240/415V
  • Operating voltage range: 207V ~ 253V
  • Voltage tolerance: 184V ~ 264V
  • Nominal current: 250A/50mA
  • Frequency: 50Hz / 60Hz
  • Display: LCD with LED indicators
  • Communication protocol: ModBus-RTU
  • Interface: RS485
  • Communication speeds: 1200/2400/4800/9600 bps (optionally 19200/115200 bps)
  • Measurement parameters: Active/reactive energy (kWh, kvarh), Capacity (kW, kvar, kVA), RMS current (Irms), RMS voltage (Vrms) and others
  • Operating temperature: -25°C to +55°C
  • Storage temperature: -40°C to +70°C
  • Humidity: 95% (non-condensing)
  • Atmospheric pressure: 63.0 kPa to 106.0 kPa
  • Dimensions: 72mm x 100mm x 65.5mm
  • Mounting: DIN rail 35mm

Manufacturer

Specifications

Display Type
Digital
Installation Type
Rail
Number of Phases
Three-phase

Smart Features

Connectivity
Modbus

Important information