Name: Digital Single-Phase Voltage Protection Relay
Model: SVP-917-80A
Main functions: protection against overvoltage, undervoltage, and overloads; LED display for voltage, current, and kWh consumption; adjustable current range between 1-80 A; option for auto/manual reset.
Technical Specifications:
- Rated voltage: 85-300 V AC
- Adjustable overvoltage protection: 85-300 V (default values: overvoltage 270 V, return 250 V)
- Adjustable undervoltage protection: 85-300 V (default values: undervoltage 170 V, return 180 V)
- Adjustable current protection: 16-3 A typical, option 1-80 A
-
Adjustable delays:
- Power-on delay (2-55 s)
- Release time from overvoltage/undervoltage (0.1-10 s)
- Release time from overload (0.15-12 s)
- Auto reset time (2-12 s)
- Display: dual LED for voltage and current, plus digital display for energy consumption in kWh (0-9999.9 kWh)
- Accuracy: 0.5% for voltage/current/power; 1% for active energy
- Operating temperature: -25°C to +70°C (operation), -40°C to +80°C (storage)
- Humidity: 85% relative
- Altitude: 2500 m
Features:
- Protection against overvoltage, undervoltage, and overloads with adjustable parameters.
- Continuous display for voltage, current, active power, and energy consumption.
- Reset functions: automatic or manual (selectable).
- Flexible operating modes: active protection, switch only, on/off cycle, etc.
- Visible LED indicators: flashing for errors, steady for normal conditions.
- Error history: error codes are displayed for recent events.
Wiring Diagram:
- REEA (Source)
- L in [Protector SVP-917-80A] L out Protected circuit
- N in [Protector SVP-917-80A] N out Protected circuit
Diagram description:
- L in (Input phase): Phase connector from the main grid.
- N in (Input neutral): Neutral connector from the grid.
- L out (Output phase): Output phase to the load (protected circuit).
- N out (Output neutral): Output neutral to the protected circuit.
It is essential that phases and neutrals are connected properly according to the device markings.
Installation Notes:
- A separate protective device (circuit breaker) must be used for short-circuit protection.
- Connections must be made with copper conductors, tightly secured for reliable contact.
- Mounting on 35 mm DIN rail.
Indicators and Behavior:
-
Voltage indicator (LED):
- Normal condition: solid on
- Overvoltage: rapid flashing
- Undervoltage: slow flashing
-
Current indicator (LED):
- Normal condition: solid on
- Overload: flashing
- Energy consumption: displayed on the digital screen with decimal (e.g. 1234.5 kWh)
- Error code: displays code (UL, UH, IH, etc.) for the last error.
Configuration:
- Press and hold the SET button for 3 seconds to enter setting mode.
- Use the up/down buttons to modify parameter values: limits, times, reset mode.
- Press SET again to save and exit setting mode.
- If there is no interaction for about 30 seconds in setting mode, it automatically returns to the normal screen without saving.
- To reset to factory defaults, press both up and down buttons simultaneously for 3 seconds.
Useful Notes:
- Confirm correct connections before powering on.
- If protection is triggered frequently, check power supply quality or inspect connected loads.
- For testing, simulate a slight overvoltage or current above the limit to verify functions.
- Do not touch live terminals; only perform electrical work with power turned off.