Electric Panel Meters

Sinotimer Electric Panel Meter Digital Rail Single Phase

Name: Digital Voltage Protection Relay, Single-Phase

Model: SVP-917-63A

  • Important Functions: overvoltage protection, undervoltage protection, overcurrent protection, energy consumption display (kWh),...

Name: Digital Voltage Protection Relay, Single-Phase

Model: SVP-917-63A

  • Important Functions: overvoltage protection, undervoltage protection, overcurrent protection, energy consumption display (kWh), adjustable range 1–63 A, automatic reset.

Technical Specifications:

  • Current protection range: 1 – 63 A (default 40 A; option up to 80 A with special order)
  • ...
See full description See full description
The product is not available for shipping to the selected country.

Description

Description

Name: Digital Voltage Protection Relay, Single-Phase

Model: SVP-917-63A

  • Important Functions: overvoltage protection, undervoltage protection, overcurrent protection, energy consumption display (kWh), adjustable range 1–63 A, automatic reset.

Technical Specifications:

  • Current protection range: 1 – 63 A (default 40 A; option up to 80 A with special order)
  • Adjustable overvoltage limit: 85 – 300 V (default ~270 V)
  • Adjustable undervoltage limit: 85 – 300 V (default ~170 V)
  • Startup delay time: 2 – 255 s (default 2 s)
  • Power consumption (voltage circuit): ~1 W, weight < 1 VA
  • Active energy display: 0 – 9999.9 kWh
  • Current/voltage accuracy: ±0.5 %
  • Active energy accuracy: ±1 % (according to IEC62053-21 standard)
  • Rated frequency: 50 / 60 Hz
  • Operating temperature: –25 °C … +70 °C
  • Storage temperature: –40 °C … +80 °C
  • Permissible relative humidity: ≤ 85 %
  • Maximum operating altitude: up to 2,500 m
  • Dimensions (L × W × H): approximately 100 × 36 × 67.5 mm
  • Material: combined plastic and metal housing

Features and Operation:

  • Overvoltage protection: The relay disconnects the power supply if the voltage exceeds the set limit.
  • Undervoltage protection: The relay disconnects if the voltage falls below the set limit.
  • Overcurrent protection: The circuit is automatically protected if the current exceeds the set limit between 1–63 A.
  • Consumption display (kWh): Total consumption is shown on the digital display.
  • Automatic reset: After disconnection, power is restored automatically when conditions return to normal.
  • Dual current/voltage display: Continuous monitoring of operating parameters.
  • Warning codes: Display of the latest fault codes for easy diagnosis.

Installation and Operating Instructions:

  • Mounting: on a 35 mm DIN rail inside an electrical panel.
  • Connections:
    • Input: phase (L) and neutral (N) from the mains.
    • Output: phase and neutral to the protected circuit.
  • Initial settings:
    • Overvoltage and undervoltage limits.
    • Current limit.
    • Startup delay time.
  • After power-up: check the displays (voltage, current, consumption).
  • Disconnection tests can be performed with controlled voltage variation or temporary overload.

Safety Recommendations and Terms:

  • Check the wiring before sealing.
  • Ensure that the load does not exceed the specified protection current.
  • Use only a properly connected and verified receiver, without improper contact.
  • If protection is activated, disconnect the load to avoid repeated connection/disconnection cycles.
  • This device does not replace a short-circuit breaker; use together with one is recommended.

Manufacturer

See full description

Specifications

Specifications

Display Type
Digital
Installation Type
Rail
Number of Phases
Single-phase

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

Name: Digital Voltage Protection Relay, Single-Phase

Model: SVP-917-63A

  • Important Functions: overvoltage protection, undervoltage protection, overcurrent protection, energy consumption display (kWh), adjustable range 1–63 A, automatic reset.

Technical Specifications:

  • Current protection range: 1 – 63 A (default 40 A; option up to 80 A with special order)
  • Adjustable overvoltage limit: 85 – 300 V (default ~270 V)
  • Adjustable undervoltage limit: 85 – 300 V (default ~170 V)
  • Startup delay time: 2 – 255 s (default 2 s)
  • Power consumption (voltage circuit): ~1 W, weight < 1 VA
  • Active energy display: 0 – 9999.9 kWh
  • Current/voltage accuracy: ±0.5 %
  • Active energy accuracy: ±1 % (according to IEC62053-21 standard)
  • Rated frequency: 50 / 60 Hz
  • Operating temperature: –25 °C … +70 °C
  • Storage temperature: –40 °C … +80 °C
  • Permissible relative humidity: ≤ 85 %
  • Maximum operating altitude: up to 2,500 m
  • Dimensions (L × W × H): approximately 100 × 36 × 67.5 mm
  • Material: combined plastic and metal housing

Features and Operation:

  • Overvoltage protection: The relay disconnects the power supply if the voltage exceeds the set limit.
  • Undervoltage protection: The relay disconnects if the voltage falls below the set limit.
  • Overcurrent protection: The circuit is automatically protected if the current exceeds the set limit between 1–63 A.
  • Consumption display (kWh): Total consumption is shown on the digital display.
  • Automatic reset: After disconnection, power is restored automatically when conditions return to normal.
  • Dual current/voltage display: Continuous monitoring of operating parameters.
  • Warning codes: Display of the latest fault codes for easy diagnosis.

Installation and Operating Instructions:

  • Mounting: on a 35 mm DIN rail inside an electrical panel.
  • Connections:
    • Input: phase (L) and neutral (N) from the mains.
    • Output: phase and neutral to the protected circuit.
  • Initial settings:
    • Overvoltage and undervoltage limits.
    • Current limit.
    • Startup delay time.
  • After power-up: check the displays (voltage, current, consumption).
  • Disconnection tests can be performed with controlled voltage variation or temporary overload.

Safety Recommendations and Terms:

  • Check the wiring before sealing.
  • Ensure that the load does not exceed the specified protection current.
  • Use only a properly connected and verified receiver, without improper contact.
  • If protection is activated, disconnect the load to avoid repeated connection/disconnection cycles.
  • This device does not replace a short-circuit breaker; use together with one is recommended.

Manufacturer

Display Type
Digital
Installation Type
Rail
Number of Phases
Single-phase

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.