Expansion Tanks

Heating Expansion Tank Vertical 50lt Code: GF-0726

HIDROFOR Expansion Vessel 50L, 6 bar, 1". The Micul Fermier GF-0726 Expansion Vessel is multifunctional with a reversible membrane, suitable for heating and water supply systems. It is ideal for...

HIDROFOR Expansion Vessel 50L, 6 bar, 1". The Micul Fermier GF-0726 Expansion Vessel is multifunctional with a reversible membrane, suitable for heating and water supply systems. It is ideal for heating, cooling, drinking water, and solar energy applications.

The vessel is installed horizontally on a self-supporting base, with a side connection. Capacity: 50...

See full description See full description
The product is not available for shipping to the selected country.

Description

Description

HIDROFOR Expansion Vessel 50L, 6 bar, 1". The Micul Fermier GF-0726 Expansion Vessel is multifunctional with a reversible membrane, suitable for heating and water supply systems. It is ideal for heating, cooling, drinking water, and solar energy applications.

The vessel is installed horizontally on a self-supporting base, with a side connection. Capacity: 50 liters. The hydrophore vessel with a reversible membrane includes an air cushion that ensures the permanent maintenance of water pressure in a piping network. It is used in hydrophore systems for protection against network pressures.

Use: The hydrophore vessel is used in water supply installations for operation in hydrophore mode. It stores a quantity of water and reduces pump starts/stops as well as absorbs hydraulic shocks. The water pressure in the pressure vessel and the users' network is maintained by the air cushion. This pressure varies within the limits set by the pressure switch and is kept within these values by an electric pump, which starts and stops based on the pressure switch commands.

The air cushion is created by the air pump in the vessel through a valve located at one end of the vessel. The initial air pressure in the vessel (measured at the air valve) should be approximately 1.5 bar. The air cushion allows a quantity of water to accumulate in the vessel, which can be used without starting the pump. This quantity accumulates in the vessel each time after all consumers have been closed until the pump stops.

Technical data:

  • Construction: steel alloy, finished, painted.
  • Membrane: flexible synthetic rubber.
  • Maximum working pressure: 6 bar.

Manufacturer

See full description

Specifications

Specifications

Product Number
GF-0726

Specifications

Usage
Heating
Capacity
50 lt
Placement
Vertical
Thread
1 "
Membrane Type
-

Features

Wall-mounted
-
with Stand
No
Maximum Pressure
6 bar
Precharge Pressure
1.5 bar
Maximum Operating Temperature
-

Dimensions

Diameter
-
Height
-

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

HIDROFOR Expansion Vessel 50L, 6 bar, 1". The Micul Fermier GF-0726 Expansion Vessel is multifunctional with a reversible membrane, suitable for heating and water supply systems. It is ideal for heating, cooling, drinking water, and solar energy applications.

The vessel is installed horizontally on a self-supporting base, with a side connection. Capacity: 50 liters. The hydrophore vessel with a reversible membrane includes an air cushion that ensures the permanent maintenance of water pressure in a piping network. It is used in hydrophore systems for protection against network pressures.

Use: The hydrophore vessel is used in water supply installations for operation in hydrophore mode. It stores a quantity of water and reduces pump starts/stops as well as absorbs hydraulic shocks. The water pressure in the pressure vessel and the users' network is maintained by the air cushion. This pressure varies within the limits set by the pressure switch and is kept within these values by an electric pump, which starts and stops based on the pressure switch commands.

The air cushion is created by the air pump in the vessel through a valve located at one end of the vessel. The initial air pressure in the vessel (measured at the air valve) should be approximately 1.5 bar. The air cushion allows a quantity of water to accumulate in the vessel, which can be used without starting the pump. This quantity accumulates in the vessel each time after all consumers have been closed until the pump stops.

Technical data:

  • Construction: steel alloy, finished, painted.
  • Membrane: flexible synthetic rubber.
  • Maximum working pressure: 6 bar.

Manufacturer

Product Number
GF-0726

Specifications

Usage
Heating
Capacity
50 lt
Placement
Vertical
Thread
1 "
Membrane Type
-

Features

Wall-mounted
-
with Stand
No
Maximum Pressure
6 bar
Precharge Pressure
1.5 bar
Maximum Operating Temperature
-

Dimensions

Diameter
-
Height
-

Important information