Central Heating Parts & Accessories

Boiler Controller Heating Pumps Domestic Hot Water Pumps Fan

The ST-06 control panel regulates the central heating pump, domestic hot water pump and fan for solid fuel boilers, such as those burning wood, coal and coal dust. It features an LED display with...

The ST-06 control panel regulates the central heating pump, domestic hot water pump and fan for solid fuel boilers, such as those burning wood, coal and coal dust. It features an LED display with touch buttons and allows a room thermostat to be connected. Operation is selected from 5 available programs, depending on the fuel and boiler. The domestic hot...

See full description See full description

Top specs

See all
  • Power 2 W
The product is not available for shipping to the selected country.

Description & Specifications

The ST-06 control panel regulates the central heating pump, domestic hot water pump and fan for solid fuel boilers, such as those burning wood, coal and coal dust. It features an LED display with touch buttons and allows a room thermostat to be connected. Operation is selected from 5 available programs, depending on the fuel and boiler. The domestic hot water tank temperature is displayed by pressing the [-] button; after 3 seconds, the display automatically returns to the boiler temperature.

  • Type: Boiler control panel
  • Compatibility: Solid fuel boilers
  • Power: 2 W
  • Power supply: 230 V/50 Hz ±10%
  • Power consumption: 2 W
  • Controls: Central heating pump, domestic hot water pump and fan
  • Display: LED with touch buttons
  • Operating programs: 5
  • Room thermostat connection: Connection available
  • Ambient temperature: -10 to 50 °C
  • Pump and fan output load: 3.15 A
  • Temperature measurement range: 0 to 99 °C
  • Central heating temperature setting range: 35 to 80 °C
  • Sensor temperature tolerance: -10 to 120 °C
  • Central heating sensor cable length: 1.2 m
  • Fan sensor cable length: 1.7 m
  • Power cable length: 1.5 m
  • Blowing time: 0 to 90 seconds
  • Blowing interval: 1 to 15 minutes
  • Extinguishing temperature: 20 to 70 °C
  • Ignition time: 0 to 99 minutes
  • Emergency thermostat: 90 °C
  • Dimensions: 175 × 175 × 100 mm

Manufacturer

Dimensions

Type
Control Panel
Compatibility
for Boiler
Construction Material [Pharmaceutical]
-
Smart / WiFi
No

Technical Parameters

Thread / Cross-section
-
Power
2 W
Maximum Pressure
-

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.