The Engo EPC12HW controller manages central heating (CO) and domestic hot water (DHW) pumps. It switches on the CO pump when the boiler temperature exceeds the user-set value, while the DHW pump operates based on the temperature difference between the boiler and the tank. It includes frost protection, summer mode and DHW priority.
- Compatibility: Boiler
- Functions: Frost protection at 5 °C, “antistop” function, summer mode, DHW priority
- Alarm: Audible high-temperature alarm
- Power supply: 230 V AC, 50 Hz
- Maximum CO pump load: 3(1) A
- Maximum DHW pump load: 3(1) A
- Temperature measurement range: 0–99 °C
- CO temperature setting: 5–80 °C
- DHW temperature setting: 20–80 °C
- Sensor operating range: -10–120 °C
- CO sensor cable length: 1.5 m
- DHW sensor cable length: 3 m
- Dimensions: 155 × 70 × 39 mm
Dimensions
- Type
- Control Panel
- Compatibility
- for Boiler
- Construction Material [Pharmaceutical]
- -
- Smart / WiFi
- No
Technical Parameters
- Thread / Cross-section
- -
- Power
- -
- Maximum Pressure
- -
Important information
Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.