Misc Industrial Building Equipment

F&f Current Transducer 0-15a Output 4-20ma 9-30v Dc Ac-1i 15a

The F&f Current Transducer converts the measured current into a 4–20 mA output signal. True RMS measurement covers AC currents up to 15 A and DC currents up to 20 A.

  • Supply voltage: 9–30 V DC
  • True...

The F&f Current Transducer converts the measured current into a 4–20 mA output signal. True RMS measurement covers AC currents up to 15 A and DC currents up to 20 A.

  • Supply voltage: 9–30 V DC
  • True RMS measurement range: 0–15 A AC, 0–20 A DC
  • Maximum voltage: 285 V AC, 400 V DC
  • Permissible overload: 100 A for 100 ms
  • Maximum measurement error: 0.2 A
  • Output...
See full description See full description
The product is not available for shipping to the selected country.

Description

Description

The F&f Current Transducer converts the measured current into a 4–20 mA output signal. True RMS measurement covers AC currents up to 15 A and DC currents up to 20 A.

  • Supply voltage: 9–30 V DC
  • True RMS measurement range: 0–15 A AC, 0–20 A DC
  • Maximum voltage: 285 V AC, 400 V DC
  • Permissible overload: 100 A for 100 ms
  • Maximum measurement error: ±0.2 A
  • Output signal: 4–20 mA
  • Maximum output signal cable length: 300 m
  • Breakdown voltage WE→WY: 2.1 kV
  • Conversion error: ±0.5%
  • Power consumption: 0.8 W
  • Operating temperature: -20–50 °C
  • Connection: 2.5 mm² screw terminals
  • Dimensions: 1 module (18 mm)
  • Mounting: On a TH-35 rail
  • Protection rating: IP20

Manufacturer

See full description

Specifications

Specifications

Type
Converter

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The F&f Current Transducer converts the measured current into a 4–20 mA output signal. True RMS measurement covers AC currents up to 15 A and DC currents up to 20 A.

  • Supply voltage: 9–30 V DC
  • True RMS measurement range: 0–15 A AC, 0–20 A DC
  • Maximum voltage: 285 V AC, 400 V DC
  • Permissible overload: 100 A for 100 ms
  • Maximum measurement error: ±0.2 A
  • Output signal: 4–20 mA
  • Maximum output signal cable length: 300 m
  • Breakdown voltage WE→WY: 2.1 kV
  • Conversion error: ±0.5%
  • Power consumption: 0.8 W
  • Operating temperature: -20–50 °C
  • Connection: 2.5 mm² screw terminals
  • Dimensions: 1 module (18 mm)
  • Mounting: On a TH-35 rail
  • Protection rating: IP20

Manufacturer

Type
Converter

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.