Relays

Bosch Flm-420-rhv-s Surface Relay Unit High Voltage 2 Outputs

The Bosch FLM-420-RHV-S surface-mounted high-voltage relay module controls external devices, such as smoke exhaust dampers and fans, on an LSN local network. It is compatible with FPA-5000 and...

The Bosch FLM-420-RHV-S surface-mounted high-voltage relay module controls external devices, such as smoke exhaust dampers and fans, on an LSN local network. It is compatible with FPA-5000 and FPA-1200 fire alarm panels and includes built-in short-circuit isolators and LED indicators.

  • Outputs: 2 Form C changeover relays
  • Input voltage: 15 VDC - 33 VDC
  • ...
See full description See full description
The product is not available for shipping to the selected country.

Description

Description

The Bosch FLM-420-RHV-S surface-mounted high-voltage relay module controls external devices, such as smoke exhaust dampers and fans, on an LSN local network. It is compatible with FPA-5000 and FPA-1200 fire alarm panels and includes built-in short-circuit isolators and LED indicators.

  • Outputs: 2 Form C changeover relays
  • Input voltage: 15 VDC - 33 VDC
  • Maximum current consumption: 17.15 mA
  • Maximum contact load: 10 A at 120 VAC, 10 A at 230 VAC, 10 A at 24 VDC, 6 A at 30 VDC
  • Maximum NC contact delay time: 9 ms
  • Operating temperature: -20 °C to +50 °C
  • Storage temperature: -25 °C to +85 °C
  • Enclosure protection rating: IP 54

Manufacturer

See full description

Specifications

Specifications

Voltage
-
Current
10 A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The Bosch FLM-420-RHV-S surface-mounted high-voltage relay module controls external devices, such as smoke exhaust dampers and fans, on an LSN local network. It is compatible with FPA-5000 and FPA-1200 fire alarm panels and includes built-in short-circuit isolators and LED indicators.

  • Outputs: 2 Form C changeover relays
  • Input voltage: 15 VDC - 33 VDC
  • Maximum current consumption: 17.15 mA
  • Maximum contact load: 10 A at 120 VAC, 10 A at 230 VAC, 10 A at 24 VDC, 6 A at 30 VDC
  • Maximum NC contact delay time: 9 ms
  • Operating temperature: -20 °C to +50 °C
  • Storage temperature: -25 °C to +85 °C
  • Enclosure protection rating: IP 54

Manufacturer

Voltage
-
Current
10 A

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.