Automatic Circuit Breaker

Eaton Automatic Circuit Breaker 40A Four Pole AC 235410

The window/busbar-type terminals are located at the top and bottom, ensuring easy access with the busbar installed. The Z-HK and Z-NHK auxiliary contacts are mounted on the side, with contact position...

The window/busbar-type terminals are located at the top and bottom, ensuring easy access with the busbar installed. The Z-HK and Z-NHK auxiliary contacts are mounted on the side, with contact position indication in red and green. It is suitable for use with conventional luminaires, with or without electronic ignition, up to 20 units per phase. The switch...

See full description See full description

Learn more about invoicing

Description

Description

The window/busbar-type terminals are located at the top and bottom, ensuring easy access with the busbar installed. The Z-HK and Z-NHK auxiliary contacts are mounted on the side, with contact position indication in red and green. It is suitable for use with conventional luminaires, with or without electronic ignition, up to 20 units per phase. The switch position and supply direction are arbitrary. The disconnection is independent of the mains voltage. The 4-pole switch can be used as a 3-pole switch with terminals 1-2, 3-4 and 5-6 (+ busbar bridge), or as a 2-pole switch with terminals 5-6 and N-N. Monthly testing is recommended by pressing the “Test” button, where the switch must trip. The test checks the disconnection due to leakage current and does not replace the measurement of the earth resistance RE and the insulation resistance of the conductors.

Technical characteristics:

  • Number of poles: 4
  • Rated voltage: 400V 50Hz
  • Rated current: 40A
  • Rated short-circuit capacity: 1kA
  • Impulse current withstand: 0.25kA
  • Short-circuit capacity: 10 kA
  • Sensitivity: AC
  • Mounting depth: 69.5mm
  • Installation: TS35 rail
  • Degree of protection: IP20

Manufacturer

See full description

Specifications

Specifications

Specifications

Number of Poles
4
Rated Current
40 A

Power Supply

AC
Yes
DC
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

See all specifications

Description & Specifications

The window/busbar-type terminals are located at the top and bottom, ensuring easy access with the busbar installed. The Z-HK and Z-NHK auxiliary contacts are mounted on the side, with contact position indication in red and green. It is suitable for use with conventional luminaires, with or without electronic ignition, up to 20 units per phase. The switch position and supply direction are arbitrary. The disconnection is independent of the mains voltage. The 4-pole switch can be used as a 3-pole switch with terminals 1-2, 3-4 and 5-6 (+ busbar bridge), or as a 2-pole switch with terminals 5-6 and N-N. Monthly testing is recommended by pressing the “Test” button, where the switch must trip. The test checks the disconnection due to leakage current and does not replace the measurement of the earth resistance RE and the insulation resistance of the conductors.

Technical characteristics:

  • Number of poles: 4
  • Rated voltage: 400V 50Hz
  • Rated current: 40A
  • Rated short-circuit capacity: 1kA
  • Impulse current withstand: 0.25kA
  • Short-circuit capacity: 10 kA
  • Sensitivity: AC
  • Mounting depth: 69.5mm
  • Installation: TS35 rail
  • Degree of protection: IP20

Manufacturer

Specifications

Number of Poles
4
Rated Current
40 A

Power Supply

AC
Yes
DC
No

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

139,90 €
14,00 €   shipping cost