Technical Documentation
Model: SINOTIMER SVP-717
Product type: Multifunctional digital relay for protection and monitoring of single-phase electrical networks, DIN rail mounted.
Features
- Operating / voltage measurement: AC 80–300 V
- Maximum rated current (Ie): 63 A
- Overvoltage protection: Adjustable AC 130–300 V
- Undervoltage protection: Adjustable AC 80–210 V
- Overcurrent protection: Adjustable, up to 63 A
- Reconnection time: Adjustable 1–600 s
- Voltage measurement: Yes, V
- Current measurement: Yes, A
- Frequency measurement: Yes, Hz
- Active power measurement: Yes, W / kW
- Energy measurement: Yes, kWh
- Energy meter range: 0–9999 kWh
- Maximum indicated apparent power: 63 kVA
- Display: Digital multicolor
- Manual output control: Yes, ON/OFF button
- Network: Single-phase, L + N
- Mounting: On DIN rail
Functions
The SINOTIMER SVP-717 is a 5-in-1 device designed for the protection and monitoring of a single-phase installation. The device provides protection against overvoltage, undervoltage and overcurrent, as well as monitoring of electrical parameters and energy consumption measurement. When one of the monitored parameters exceeds the programmed limits, the device disconnects the load. After the network returns within acceptable limits, power is restored after the set reconnection time.
Configurable parameters
The digital display allows monitoring of the following:
- V – voltage
- A – current
- Hz – frequency
- W / kW – instantaneous power
- kWh – cumulative electrical energy
Configuration is done via the SET button and the ▲ / ▼ keys. The Power button allows manual ON/OFF control of the output.
Electrical connection
- Input – upper side:
- 1 – N: neutral input
- 3 – L: phase input
- Output – lower side:
- 2 – N: neutral output
- 4 – L: phase output
Installation and safety
The SVP-717 is installed in the electrical panel on a DIN rail. Installation must be carried out with the power supply turned off and by authorized personnel, strictly observing the Input/Output interfaces and the L/N polarity. The device does not replace automatic short-circuit protection or RCD/RCBO protection. These protections must be used separately, according to the configuration of the electrical installation.