Electric Panel Meters

FF Professional Kilowatt Meter for Electrical Panel Rail Three-Phase Modbus LAN

The FF Professional LE-03ETH-CT three-phase DIN-rail kilowatt-hour meter measures active and reactive energy bidirectionally, as well as phase voltages and currents, frequency, and active and reactive...

The FF Professional LE-03ETH-CT three-phase DIN-rail kilowatt-hour meter measures active and reactive energy bidirectionally, as well as phase voltages and currents, frequency, and active and reactive power. It works with current and voltage transformers and supports remote data reading and management via Ethernet and Modbus TCP. It is compatible with the LE...

See full description See full description

Top specs

See all
  • Connectivity Modbus, LAN
426 51 €
Delivery Thu, 26 Nov - Wed, 02 Dec
14,00 €   shipping cost
Sent from Greece
From Getters 4.5 (118)

Learn more about invoicing

Description & Specifications

The FF Professional LE-03ETH-CT three-phase DIN-rail kilowatt-hour meter measures active and reactive energy bidirectionally, as well as phase voltages and currents, frequency, and active and reactive power. It works with current and voltage transformers and supports remote data reading and management via Ethernet and Modbus TCP. It is compatible with the LE Config and MeternetPRO software and is MID certified.

  • Type: Kilowatt-hour meter
  • Installation: 35 mm DIN rail
  • Number of phases: Three-phase
  • Connectivity: Modbus TCP, Ethernet
  • Rated current: 5 A
  • Maximum current: 3×6 A
  • Minimum measured current: 0.02 A
  • Basic current: 3×5 A
  • Operating voltage: 400 V
  • Rated voltage: 3×230/400 V
  • Power supply: 85–275 V AC
  • Frequency: 50 Hz
  • Power consumption: 10 VA, 2 W
  • Meter display range: 0–99999999.9 kWh
  • Phase voltage measurement range: 100–276 V AC (1p2w and 3p4w)
  • Line-to-line voltage measurement range: 172–480 V AC (3p3w)
  • Current input power: Less than 1 VA
  • Voltage accuracy: 0.5%
  • Current accuracy: 0.5%
  • Frequency accuracy: 0.2%
  • Power factor accuracy: 1%
  • Active and reactive power accuracy: ±1%
  • Active energy accuracy: EN504070-32022, Class B
  • Reactive energy accuracy: IEC62053-23, Class 2
  • Insulation: 4 kV/1 min, 6 kV/1.2 µs
  • Operating temperature: -40–70 °C
  • Dimensions: 4 modules (70 mm)
  • Measurement category: CAT III
  • Protection rating: IP51
  • Reading indicator: Red LED
  • Default IP address: 192.168.1.200
  • Port: 502
  • Subnet mask: 255.255.255.0
  • Gateway: 192.168.1.1
  • DHCP: Disabled

Manufacturer

Specifications

Type
Kilowatt meter
Installation Type
Rail
Number of Phases
Three-phase
Maximum Current
5 A

Smart Features

Connectivity
Modbus, LAN

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.

426,51 €
14,00 €   shipping cost