Electrical Panel Push Buttons Switches

Sinotimer DIN Rail Button 230V 16A

The SINOTIMER AFDD AFDD2-63 B16 switch is a 4-in-1 protection device for single-phase 1P+N electrical circuits at 230 V AC. It combines arc fault detection (AFDD), residual current protection,...

The SINOTIMER AFDD AFDD2-63 B16 switch is a 4-in-1 protection device for single-phase 1P+N electrical circuits at 230 V AC. It combines arc fault detection (AFDD), residual current protection, overload protection and short-circuit protection.

The model has a rated current of 16 A, a B tripping characteristic and a residual current sensitivity of 30 mA. The...

See Description & Specifications See Description & Specifications
The product is not available for shipping to the selected country.

Description & Specifications

The SINOTIMER AFDD AFDD2-63 B16 switch is a 4-in-1 protection device for single-phase 1P+N electrical circuits at 230 V AC. It combines arc fault detection (AFDD), residual current protection, overload protection and short-circuit protection.

The model has a rated current of 16 A, a B tripping characteristic and a residual current sensitivity of 30 mA. The AFDD function monitors the circuit for dangerous electrical arcs, which can result from loose connections, damaged conductive materials, faulty insulation or poor electrical contacts.

The device features TEST and RESET buttons, as well as indicator lights for operation and fault identification. A front window allows the mechanism’s status to be monitored.

Its compact design allows it to be installed directly in an electrical panel on a standard 35 mm DIN rail.

4-in-1 protection
  • AFDD – arc fault detection
  • 30 mA residual current protection – residual current detection
  • Overload protection
  • Short-circuit protection

By combining these functions in a single device, the AFDD2-63 provides excellent circuit protection while taking up minimal space in the distribution panel.

Technical specifications Feature Specification Brand SINOTIMER Model AFDD2-63 Variant B16 Product type AFDD circuit breaker Number of poles 1P+N Network type Single-phase Rated current 16 A Tripping characteristic B Voltage marked on the product 230 V AC Frequency 50 Hz Rated residual operating current IΔn 30 mA Operating time marked on the product ≤0.1 s Breaking capacity 4500 A / 4.5 kA Arc fault protection Yes – AFDD Residual current protection Yes Overload protection Yes Short-circuit protection Yes Residual current protection type Type AC TEST button Yes RESET button Yes RUN indicator Yes – green GF indicator Yes – red AF indicator Yes – yellow Installation DIN rail DIN rail 35 mm Width Approx. 53 mm Height Approx. 96 mm Maximum depth Approx. 73 mm Depth on DIN rail Approx. 45 mm Certification marked on the product CE Standards marked on the device IEC 61009-1, IEC 62606 AFDD standard marked on the device GB/T 31143

AFDD function – arc fault protection

The AFDD (Arc Fault Detection Device) monitors the electrical circuit for characteristic signals of a dangerous arc fault. Such faults can be caused by:

  • Loose electrical connections
  • Damaged wires or insulation
  • Poor contacts
  • Mechanically damaged conductive materials
  • Connections that generate heat and electrical arcs

Detecting an arc fault allows the protection device to interrupt operation and helps reduce the risk of overheating and electrical fires.

30 mA residual current protection

The device provides residual current protection with a rated sensitivity of 30 mA. This function monitors current imbalance in the circuit and trips the device when the tripping conditions are met.

Overload and short-circuit protection

The AFDD2-63 B16 includes thermal-magnetic protection, with:

  • Rated current: 16 A
  • Characteristic: B
  • Breaking capacity: 4500 A / 4.5 kA

A B characteristic is used for circuits where inrush currents are not particularly high. The final protection rating should be selected according to the installation and connected loads.

Front indicators

The device has three indicators:

  • RUN – green: indicates that the device is operating.
  • GF – red: indicator related to a ground fault.
  • AF – yellow: indicator related to arc fault detection.

The front mechanical window also allows the device’s status to be monitored.

TEST and RESET buttons

The orange TEST button allows you to check that the protection system is working. The blue RESET button is used to reset the device according to the operating procedure.

Manufacturer

Specifications

Panel Switches Type
Button
Nominal Voltage
230 V
Rated Voltage
16 A

Features & Functions

WiFi
No

Important information