Special Measuring Instruments

Basic Combustion Analyzer Ee Calibration Certificate

The FORENSICS DETECTORS FD-4A-FLUE combustion analyzer measures oxygen (O2) and carbon monoxide (CO), and calculates carbon monoxide air-free (COAF) and excess air (EA). It is used for combustion...

The FORENSICS DETECTORS FD-4A-FLUE combustion analyzer measures oxygen (O2) and carbon monoxide (CO), and calculates carbon monoxide air-free (COAF) and excess air (EA). It is used for combustion analysis in residential boilers, heaters and furnaces, as well as for ambient air quality measurements. With the pump and sensor, it can be used as a spot detector...

See Description & Specifications See Description & Specifications
The product is not available for shipping to the selected country.

Description & Specifications

The FORENSICS DETECTORS FD-4A-FLUE combustion analyzer measures oxygen (O2) and carbon monoxide (CO), and calculates carbon monoxide air-free (COAF) and excess air (EA). It is used for combustion analysis in residential boilers, heaters and furnaces, as well as for ambient air quality measurements. With the pump and sensor, it can be used as a spot detector or as a combustion and flue gas analyzer.

The large LCD has a backlight, and the electrochemical O2 and CO sensors have a lifespan of 2–3 years. The device does not measure flue gas temperature, calculate combustion efficiency or detect carbon dioxide (CO2). It is not intended for measuring vehicle exhaust gases.

  • Digital: Yes
  • Measured gases: Oxygen (O2) and carbon monoxide (CO)
  • O2 measurement range: 0–30%
  • O2 resolution: 0.1%
  • CO measurement range: 0–999 ppm
  • CO resolution: 1 ppm
  • Calculations: Carbon monoxide air-free (COAF) and excess air (EA)
  • Sensor type: Electrochemical
  • Sensor lifespan: 2–3 years
  • Display: Backlit LCD
  • Pump: Electronic, with stainless steel probe
  • Pump flow rate: 0.5 LPM
  • Response time: Up to 30 seconds
  • Accuracy: ≤ ±5% F.S.
  • Operating pressure: 1.0 bar nominal, 0.8–1.2 bar range
  • Recommended calibration interval: 12 months
  • Certificate: Signed and dated calibration certificate
  • Calibration standard in Europe: Gas source traceable to the European NPL
  • Analyzer operating temperature: −18 to 50 °C
  • Pump-probe operating temperature: 0 to 60 °C
  • Maximum flue gas exposure temperature at the probe: 400 °F for up to 3 minutes
  • Pump-probe humidity: Below 95% RH, non-condensing
  • Pump-probe power supply: Rechargeable 3.0 V DC, 1800 mAh lithium battery
  • Charging: Via USB port
  • Pump noise: Below 60 dB
  • Housing material: ABS plastic
  • Package contents: Hard aluminium case, analyzer with CO and O2 sensors, niobium magnets, electronic pump with stainless steel probe, probe assembly, 3-foot high-temperature silicone tubing, water trap, particulate filters, NOx filters with sensor cap, sensor cap mounting screw, USB charging cable, USB charger, calibration certificate and user manual

Manufacturer

Digital
Yes

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.