Special Measuring Instruments

Oxygen Analyzer Zirconia Ppm Levels 0.1 Ppm Usa Nist Traceable

The FORENSICS DETECTORS FD-OXY2000 digital oxygen analyzer measures O concentrations from 0.1 ppm to 21%, with automatic switching between four measurement ranges. Its solid-state zirconia sensor has...

The FORENSICS DETECTORS FD-OXY2000 digital oxygen analyzer measures O concentrations from 0.1 ppm to 21%, with automatic switching between four measurement ranges. Its solid-state zirconia sensor has a service life of over 5 years. The built-in sampling pump and adjustable flow valve support gas sampling.

Readings are displayed on an LCD, while the 4–20 mA...

See Description & Specifications See Description & Specifications
The product is not available for shipping to the selected country.

Description & Specifications

The FORENSICS DETECTORS FD-OXY2000 digital oxygen analyzer measures O₂ concentrations from 0.1 ppm to 21%, with automatic switching between four measurement ranges. Its solid-state zirconia sensor has a service life of over 5 years. The built-in sampling pump and adjustable flow valve support gas sampling.

Readings are displayed on an LCD, while the 4–20 mA and RS485 Modbus outputs allow connection to control networks. It features dual alarm relay outputs with an adjustable oxygen activation point, and includes a calibration certificate using a gas source traceable to the US NIST.

  • Measurement gas: Oxygen (O₂)
  • Measurement range: 0.1 ppm to 21%
  • Automatic range selection: 4 ranges (A, B, C, and D)
  • Range A: 0.1–10.0 ppm
  • Range A resolution: 0.1 ppm
  • Range A error: ±0.2 ppm
  • Range B: 10.0–100.0 ppm
  • Range B resolution: 0.1 ppm
  • Range B error: ±2.0 ppm
  • Range C: 100–1000 ppm
  • Range C resolution: 1 ppm
  • Range C error: ±20.0 ppm
  • Range D: 0.10%–25.00%
  • Range D resolution: 0.10%
  • Range D error: ±0.25%
  • Repeatability: ±2% of reading
  • Sensor: Solid-state zirconia
  • Sensor service life: Over 5 years
  • Display: Digital LCD
  • Communication outputs: 4–20 mA and RS485 Modbus
  • Alarm relay outputs: Dual output, 50 W, with adjustable oxygen activation point
  • Sampling pump: Built-in
  • Flow control valve: Included, adjusted via rotary knob
  • Flow range: 0–0.6 LPM
  • Air inlet connection: 1/4-inch fitting and 1/2-inch thread
  • Warm-up time: 15 minutes
  • Calibration: Via computer and RS485 Modbus connection
  • Recommended calibration interval: 12 months
  • Explosion protection certification: ATEX Ex ib IIC T4 Gb
  • Power supply: 110–220 VAC
  • Dimensions: 26 × 4 × 38.5 cm
  • Weight: 4 kg
  • Package contents: Zirconia oxygen analyzer, power cable, 3-foot silicone tube, user manual, hard carrying case, and calibration certificate

Manufacturer

Digital
Yes

Important information

Specifications are collected from official manufacturer websites. Please verify the specifications before proceeding with your final purchase. If you notice any problem you can report it here.